Resetting back to factory defaults when EDID has been previously stored:
1) Power off the 7600 Series transmitter
2) Disconnect any display from the 7600 HDMI® input
3) Power on your 7600 Transmitter unit.
4) Press and hold for approximately 3 seconds the ‘Capture EDID’ button to erase stored EDID
information.
5) The Video LED should flash for confirmation.
EDID Function
Operating Tips
Video Adjust Switch
On the front panel of both the transmitter and the receiver is the VIDEO ADJ (adjust) Switch.
In some installations, due to the length or quality of the HDMI® cable being used, it may be
necessary to use the opposite phase of the pixel clock to clock the HDMI® data into the trans-
mitter or into the monitor from the receiver.
If you experience color distortion on vertical edges of the video image, use the opposite set-
ting of the switch on either the transmitter or the receiver or both.
Using 9-Volt Battery
The 7600 transmitter unit can be temporarily powered using a 9V battery making it very easy
to bring the transmitter to a ceiling mounted projector for EDID capture and storage!
If you receive unexpected display results, you may be operating the 7600 using EDID informa-
tion that was stored during a previous installation. Try clearing any stored EDID information.