Fiberlink® 3355 Series

Operating Pointers

Remember to check attenuation of the fiber optic cable. The system will only operate 
properly if these specifications fall within the range of the system’s loss budget.

Note: If no signal is applied to the 3355 Transmitter, no optical power will be present on the 
3355 Transmitter’s output.

Troubleshooting

Multimode fiber optic cable contains an optical fiber with a light carrying “core” that is 
only .0025 inches (62.5 microns) in diameter. Single mode fiber optic cable has an even 
smaller “core,” only .00032 to .0004 inches (8-10 microns). This is smaller than a human hair! 
Therefore, any minute particles of dirt or dust can easily block the fiber from accepting or 
radiating light. To prevent this from happening, always use the provided dust caps when 
ever optical connectors are exposed to air. It is also a good idea to gently clean the tip of an  
optical connector with a lint-free cloth moistened with alcohol whenever dust is suspected. 

The status of the LEDs should provide the first clue as to the origin of any operational  
failure. If these are off, it usually means that the fiber is broken or has too much attenuation.  
Next, be certain that the input and output signal connections are correct.

An optical power meter, such as the Fiberlink® 6615, a visible light source, such as the  
Fiberlink® 6610, and a Three Wavelength Light Source, such as the Fiberlink® 6620, can 
greatly assist and expedite troubleshooting of fiber optic transmission systems and are 
recommended tools all installers should have available.

Finally, although multimode and single mode devices may look the same, they will not 
operate properly together. Using the wrong device or fiber can easily add more attenuation 
than specified, resulting in poor overall performance. It should be noted that some of our 
fiber optic products support both single mode and multimode fiber in the same unit.

If, after reviewing the above possibilities, the system is still not operating, please contact 
the Customer Service Department for further assistance. If you suspect your problem is 
caused by the optics or the fiber optic cable, and you have an optical power meter, please 
take the appropriate measurements prior to contacting support.

Operating Pointers | Troubleshooting

Содержание Fiberlink 3355 Series

Страница 1: ...3355 User s Manual The Fiberlink 3355 Series converts broadcast quality 3G HD SD SDI transmitted over one single mode or multimode fiber to DVI with or without embedded audio World Headquarters 5B Lyb...

Страница 2: ...echnical Specifications Model Part Number Specifications 4 General Specifications 4 Installation Instructions 6 Audio Pair Selection 7 Indicator LEDs 7 Application Diagrams 8 Operating Pointers 9 Trou...

Страница 3: ...es also provides immunity to video pathological signals over the entire link budget and operating temperature range Features Convert 3G HD SD SDI with embedded audio to DVI with audio pair selection S...

Страница 4: ...tic Input SMPTE 297 2006 Labeling PC ABCD 1310 1550 Connector LC receptacle PC polish or ST Wavelength 1100 1620 nm Minimum Input Sensitivity 17 dBm at 2 97 Gbps 20 dBm at 1 485 Gbps 23 dBm at 270 Mbp...

Страница 5: ...ignal Level 800mV 10 DC Offset 0V 0 5V Rise Fall Time 135 ps at 2 97 Gbps per SMPTE 424M 270 ps at 1 485 Gbps per SMPTE 292 0 4 ns to 1 5 ns at 270 Mbps per SMPTE 259M Overshoot 10 of amplitude Timing...

Страница 6: ...on the receiver unit 3 Optionally connect any audio cables and using the channel pair rotary selector choose your desired audio output channel Audio is also embedded on the DVI cable 4 Terminate any...

Страница 7: ...e lock at 270 Mbps Alarm On Loss of optical signal or the DVI display does not support the resolution being used Computer monitors do not support interlaced video Note The 3G HD ED and SD LEDs indicat...

Страница 8: ...Source 3355 Rx 3355 Rx 3355 Rx 3355 Rx Fiber Cable Fiber Cable Fiber Cable Fiber Cable Fiber Cable 3355 Rx Fiber Cable Fiber Cable Scan Do HD DVI or Analog RGB to 3G HD SD SDI Scan Converter Multicha...

Страница 9: ...vide the first clue as to the origin of any operational failure If these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output signal...

Страница 10: ...t transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the Fiberlink 661...

Страница 11: ...ed at its option to either the repair or replacement of defective units including free materials and labor In no event shall Artel be responsible for any incidental or consequential damages or loss of...

Страница 12: ...ical Power Meter The Fiberlink 6650 Optical Power Meter is a high ac curacy high resolution microprocessor controlled optical power meter 65 dB dynamic range calibrated to measure 850 1300 1310 and 15...

Страница 13: ...d as a stand alone 3G HD SD SDI optical link Previously serialized data is left intact throughout the entire transmission process and the 3360 Series is immune to pathological signals over the entire...

Страница 14: ...Page 14 Fiberlink 3355 Series User s Manual Fiberlink 3355 Series...

Страница 15: ...Page 15 Fiberlink 3355 Series User s Manual Fiberlink 3355 Series...

Страница 16: ...nk 3355 User s Manual World Headquarters 5B Lyberty Way Westford MA 01886 USA Tel 978 263 5775 Fax 978 263 9755 info artel com artel com 2015 Artel Video Systems All Rights Reserved Fiberlink and the...

Отзывы: