Understanding the DLC170DA Status LEDs
describes the different states of the DLC170DA status LEDs as shown in
.
Table 11.
DLC170DA Status LEDs
LED
Indicates . . .
State
Description
Alarms
Action
OK
(also
located on
the rear
panel (see
))
The DLC170DA
status
Off
If power is applied to the system,
an internal fault with the
DLC170DA may exist.
None
Replace the DLC170DA.
Green
Normal operation.
None
None.
Yellow
RX status LED may provide fault
information.
If no other status LEDs indicate a
minor alarm, then a temperature
alarm is indicated.
Minor
Address the problem
indicated by the RX
status LED if one exists. If
not, check that there is
adequate inlet and
exhaust airflow.
Red
Major alarm exists and requires
immediate attention. TX, RX, or
VIDEO status LEDs may provide
more information on the fault.
The alarm may also be the result
of an internal error.
Major
Address the problem
indicated by the TX, RX,
or VIDEO status LEDs if
one exists. If not, replace
the DLC170DA.
EMS
Element
Management
System status
Off
The DLC170DA module is in local
mode and its configuration is
controlled by the onboard
configuration switches.
None
None.
Green
The DLC170DA module is in
remote mode and the
configuration has been set by
the EMS. When in remote mode,
the actual configuration of the
module will likely not match the
settings of the configuration
switches and changing the
configuration switches will have
no effect on the module
operation.
None
None.