Art X-15 Скачать руководство пользователя страница 7

SUB-MODE

 5

In sub-mode five, there are six parameters that can be edited.
Submode five flashes the first character of the display, and
uses the other two digits to show the value. To edit the param-

eter, enter sub-mode 5, press the BYPASS button to cycle

through the parameters, and use the UP and DOWN buttons
to select the appropriate value. This table shows the display,

parameter, description, and the available settings for the

parameter.

PARAM-

DISPLAY ETER

DEFAULT

DESCRIPTION RANGE VALUE

1 System MIDI channel 1-16

1

L 2 Left pedal MIDI channel 1-16

1

r 3 Right pedal MIDI channel 1-16

1

b 4 Bypass mode 1-6

6

d

y          

5 Merger mode 

0

-

1              

0

6 Pedal inter-message delay 0-15 5

Parameter

 1 

Setting the System MIDI Channel

To set the MIDI channel for all your “system” data in-
formation both for sending and receiving, first, make sure
there is a capital “S” flashing in the display and then use

the UP/DOWN pads to select MIDI channel 1 through 16.

DEFAULT VALUE =1 (CHANNEL 1)

Parameter

 2 Setting the Left Pedal MIDI Channel

To set the MIDI channel for sending information with the Left
expression pedal, first, make sure there is a capital “L” flashing

in the display and then use the UP/DOWN pads to select
MIDI channel 1 through 16. DEFAULT VALUE =1 (CHANNEL 1)

Parameter

 3 Setting the Right Pedal MIDI Channel

To set the MIDI channel for sending information with the

Right expression pedal, first, make sure there is a lower

case “r” flashing in the display and then use the UP/

DOWN pads to select MIDI channel 1 through 16. DEFAULT

VALUE =1 (CHANNEL 1)

Parameter

 4 Setting the Bypass Function

To set the function of the BYPASS pad, first make sure there

is a lower case “b” flashing in the display. Select a value

from 1 to 6 referring to the following chart and descriptions.

 

Value Jack MIDI Momentary Toggle LED Polarity

1 X X

normal

X X

reverse

3 X X normal

4 X X

reverse

5 X X

remote

6 x x X

remote

There are two principal types of switch functions you can
choose, momentary and toggle. In momentary mode, the
state of the bypass output changes for as long as the

BYPASS button is held down mimicking directly a momen-

tary switch. Toggle mode allows for the state of the bypass

jack to change every time the BYPASS button is initially

pressed, just like an on/off switch.

When you set the value for 1 or 3, the state of the bypass

LED is the state of the bypass jack when the bypass jack is
“on” (closed), the bypass LED is lit. Values 2 or 

reverse

this, when the bypass jack is “off” (open), the bypass LED
is lit.

Value 5 acts like value 3, except instead of the bypass jack,

the MIDI port is used as the bypass output. The bypass

LED is turned on and off as in mode three, but the bypass
LED can also be remotely controlled via the MIDI port,

Mode six sends a bypass message two different ways. Both

the MIDI Out port and the 

1/4"

 jack are used to send a “Bypass”

message. The 

1/4"

 jack acts like it would in mode 1 and the

MIDI port would act as it would in mode 5. Since both a
MIDI message and the Bypass DC footswitch jack are active

the LED remains lit. If you wish momentary function only,

change the value to 1.

DEFAULT VALUE = 6 

(MIDI 84 and NORMALLY OPEN

MOMENTARY SWITCH)

Parameter

 5

 Setting the Merger On or Off

To set the function of the Merger, first make sure there is a

lower case “y” flashing in the display. Select a value of 0 or

1 Merger mode is either on (1) or off (0). When on, the MIDI

OUT acts as a software MIDI thru. When off, only messages
generated by the 

X-15

 are sent. DEFAULT VALUE 

=0

(MERGER OFF)

Parameter

 6 Setting the MIDI Inter-Message Delay

To set the inter-message delay, first make sure there is a

lower case 

"d"

 flashing in the display. Refer to the chart

below and select a value from 0 to 15. Delay times are in
milliseconds.

The inter-message delay is provided so you may limit the
amount of MIDI data sent. Limiting the amount of MIDI data

avoids the possibility of overloading the MIDI buffers. This
parameter only effects MIDI data sent by the expression
pedals. If the receiving device informs you there is an

overflow of data, increase the delay, otherwise, leave the

value set at the default setting.

VALUE

0

2

3
4
5
6
7

8
9

10

11
12
13
14
15

DELAY

0
40
80

120
160

200

240
280
320
360
400

440
480
520
560

DEFAULT VALUE = 2 

(80ms DELAY)

SUB-MODE 6:

 Dumping Parameters

Sub-mode 6 allows you to dump all your MIDI parameters from
the 

X-15

 to a MIDI storage device. Make sure your MIDI out

cable is connected to the storage device then press the MODE

and

 #6 

pad. Data will be dumped in less than five seconds.

6

Содержание X-15

Страница 1: ...mlng Examples 7 Edit Controlled Device s MIDI Program Table MPT wlth the X 15 8 Setup an ART Multiverb DR X or SGE for MIDI Control of the Pitch Parameter of the Pitch Transposer 8 Using the X 15 to Turn On or Off Effects in a Preset Uslng Effect Mode and Activator 8 APPENDIX B Connectlon Illustrations 9 10 APPENDIX C System Exclusive Messages 11 Unit Handshake Group 12 Parameter Exchange Group 12...

Страница 2: ...ts processors FEATURES Instant access of individual effects TWO real time assignable expression pedals Simple plug in and go operation DC bypass out jack for use with older units Rugged steel assembly MIDI IN OUT THRU Send MIDI data on three separate channels at once Durable composite activator pads Mode select allows multifunction use Non Volatile memory stores and remembers your changes Bright v...

Страница 3: ...encoding device which is converted done using this jack Use a standard two conductor guitar into MIDI information Try to avoid shining extremely bright cord to connect this jack to its intended termination A lights into the pedals No harm will come to the device but standard two conductor speaker cable may also be used you may affect the operation of the encoders by creating since no audio is bein...

Страница 4: ... is sent when a numbered activator pad is pressed When you enter preset mode the X 15 checks to see if a program change message has been sent since power on If one has the preset number is displayed and the associated LED for that preset will light If a program change message hasn t been sent yet the current bank is displayed Each time the X 1 5 is powered up it will default to bank one with no pr...

Страница 5: ... for Set up Mode 3 Mode six sends a bypass message two different ways Both the MIDI Out port and the 1 4 jack are used to send a Bypass message The 1 4 jack acts like it would in mode 1 and the MIDI port would act as it would in mode 5 SETUP MODE You may never need to use Setup Mode due to its complete preprogramming Read this section for all information neces sary to change settings and how Setup...

Страница 6: ...witch is pressed if it is programmed to send a MIDI message When the switch is pressed the main volume of the keyboard is toggled either to minimum or maximum ProgrammingtheBYPASS Functionto Bend a MIDI Bypass Command In this example we will enter Setup Mode and select sub mode 5 parameter 5 setting the BYPASS function for MIDI commands Flrst enter Setup Mode by pressing and holding down the MODE ...

Страница 7: ...of the bypass jack to change every time the BYPASS button is initially pressed just like an on off switch When you set the value for 1 or 3 the state of the bypass LED is the state of the bypass jack when the bypass jack is on closed the bypass LED is lit Values 2 or 4 reverse this when the bypass jack is off open the bypass LED is lit Value 5 acts like value 3 except instead of the bypass jack th...

Страница 8: ...tion is being sent out the MIDI Out port While you are in this mode press any activator pad except the MODE pad and the software version will be displayed Factory Reset To set all values of the X 15 back to factory settings you can perform a Factory Reset Press simultaneously the UP 2 and 5 buttons with the power on You may find it much easier to perform this function with your hands Factory defau...

Страница 9: ...the X 15 Use the above example as a reference substituting other parameters to be controlled For more information refer to programming examples in the the effects devices manuals Usingthe X 1 5to Turn On or Off EffectsIn a P r e s e tUsing Effect Mode and ActivatorPads You can use the X 1 5 activator pads in Effect Mode to turn certain individual effects on and off in an effects device s preset Wi...

Страница 10: ...X B CONNECTION ILLUSTRATIONS GUITAR INTO EFFECTS DEVICE CONTROLLED BY ART X 15 X 15 USED FOR MIDI CONTROL OF A SINGLE DEVICE ART X 15 IN OUT THRU MIDI IN AUDIO IN AUDIO OUT GUITAR ART X 15 IN OUT THRU MIDI IN ...

Страница 11: ... X 15 USED TO CONTROL TWO EFFECTS DEVICES KEYBOARD CONTROLLING SEPARATE DEVICE AND AN X 15 WHICH CONTROLS ONE EFFECTS DEVICE ART X 15 IN OUT THRU MIDI IN 1 THRU OUT MIDI IN 1 ART X 15 IN OUT THRU MIDI IN 1 MIDI IN 2 ART X 15 IN OUT THRU ...

Страница 12: ...ols and the hexadecimal numbering system How you actually send and receive SysEx messages is beyond the scope of this manual The X 15 SysEx messages are used to set get operating parameters determine the presence of the X 15 in a MIDI network and to verify reads and writes to the X 15 s EEPROM The general form of an X 15 SysEx message is The func byte defines the SysEx message type For the X 15 th...

Страница 13: ...X 15 to ensure it was written to the EEPROM After receiving an inbound 4D message the X 15 sends an outbound OD message The two data bytes that follow reflect the state of the X l EEPROM The first byte is always zero and the second byte can be one of four possible values 00 No EEPROM error has occurred 01 EEPROM write error 02 EEPROM read error 03 EEPROM read and write error Nothing resets these e...

Страница 14: ...ntroller numbers as shown in the first chart Use these controller numbers when assigning the pad to turn the effect on or off For ease of use assign the activator pad which is labeled with the ef fect you wish to control The next chart lists the effects you may control and the Scale value that must be assigned to work properly PAD DEFAULT VALUES PAD EFFECT 1 EXCITER 2 COMPRESSOR 3 DISTORTION 4 EQU...

Страница 15: ...r replace at its option defective product or component parts upon prepaid delivery to the factory service department or authorized service center ac companied by proof of purchase date in the form of a valid sales receipt EXCLUSIONS This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized altera tions or repairs This warranty is void if the serial ...

Отзывы: