background image

PCI2303 Data Acquisition 

 

Chapter 4 Address Assignment 

Address 0: 128 bytes MEMORY 
Address 1: 128 bytes I/O 
Address 2: 16 bytes I/O 

Function Description 

Offset 

Address 

Write Read 

0x0 

DA channel DA16 bit data

DA c

onversion status

Output Enable

Output Enable Status

0x4 

 
“Write” data format when offset address is 0: 

D31~D19 D18  D17~D16 

D15~D0 

Invalid =0 

single 

channel(default) 

Channel number 

DA data 

 

  =1 all channels 

 
“Read” data format when offset address is 0: 

D32~D1 D0 

Invalid DA

c

onversion status

                  0

DA is converted. 

                  1

DA conversion is finished. 

 

Software Process

:  

1.

 

Inquire DA conversion status; wait when the DA is converted. 

2.

 

Output new value when the DA conversion is finished. 

 
“Write” data format when offset address is 4: 

D32~D1 D0 

Invalid Output 

enabled

 

1: Off, all the voltage output is h

igh resistance

 (>1M)(default) 

0: On, outputs are normal 

 
“Read” data format when offset address is 4: 

D32~D1 D0 

Invalid 

Read back output enabled status 

 
 
 
 
 
 
 
 

BUY ONLINE at art-control.com/englishs or CALL 64861583(CN)

 

8

Содержание PCI2303

Страница 1: ...PCI2303 User s Manual Beijing ART Technology Development Co Ltd...

Страница 2: ...apter 3 Signal Connectors 6 3 1 The Definition of Signal Input and Output Connector 6 3 2 Voltage Output 6 3 3 Current Output 7 Chapter 4 Address Assignment 8 Chapter 5 Notes and Warranty Policy 9 5 1...

Страница 3: ...ge If the shipping carton and contents are damaged notify the local dealer or sales for a replacement Retain the shipping carton and packing material for inspection by the dealer Check for the followi...

Страница 4: ...out Diagram CN1 analog signal output connector 2 2 Jumper Output range selected Channel 0 XF15 XF16 XF1 XF5 XF9 Channel 1 XF13 XF14 XF2 XF6 XF10 Channel 2 XF19 XF20 XF3 XF7 XF11 Channel 3 XF17 XF18 XF...

Страница 5: ...o point adjustment potentiometer RP4 channel 1 analog output gain adjustment potentiometer RP5 channel 2 analog output zero point adjustment potentiometer RP6 channel 2 analog output gain adjustment p...

Страница 6: ...on VOUT0 VOUT3 Voltage output channels IOUT0 IOUT3 Current output channels VEE0 VEE2 External power supply input AGND Analog ground VDD Internal 16V power supply external user max can use 100mA VSS In...

Страница 7: ...0mA when the output range is 0 10mA Note Can not suspend the load when using current output Set the unused channels output mode to voltage output VOUT is D A s voltage output RS 250 or 125 RL 1K When...

Страница 8: ...data 1 all channels Read data format when offset address is 0 D32 D1 D0 Invalid DA conversion status 0 DA is converted 1 DA conversion is finished Software Process 1 Inquire DA conversion status wait...

Страница 9: ...RT products come with a limited two year warranty The warranty period starts on the day the product is shipped from ART s factory For products containing storage devices hard drives flash cards etc pl...

Страница 10: ...ent there should be installation information of the installed device in the Device Manager when the device does not work you can check this item Open Start Programs ART Demonstration Monitoring and Co...