Common Faults: 

Devices not learning in? 

 

The No.1 reason is Frequency. Confirm Dipswitch 3 & 4 are set correctly for the desired frequency. 

  The Dipswitches are only assigned on power up, so a power/down, power/up many be required. 
  A simple Test is to look at the RX-16 and trigger your wireless device. LED 1 should turn on Green. 

  If the LED doesn't turn on, its not on the correct frequency or there is a connection problem. 

Note. The LED turning on doesn't mean the device is learnt in, just that it is being detected by the RX-16. 

 

Wiring could be a problem, because the RX-16 is connected to the keypad bus you can use your multi-
meter to measure the voltage to the terminals. Please use the same Voltage tests as showing in the Key-

pad Bus Checking page. 

  Another simple test is to look at the RX-16 when trying to learn in, LED 1 will flash in sink with the key-

pad beeps. If the LED doesn't flash there is a communication problem. 

 

A device can only be learnt in once, so if you try to learn the same button or PIR into a different slot the 
Elite-S system wont let you. What you can do is a search for loaded Pendants and Detectors. 

  The Programming address for Users/Pendants is P 20 E 0 E  (when beeping starts trigger device)   

  The Programming address for Zones/PIR is P 166 E 0 E  (when beeping starts trigger device)   
  If the device is loaded the slots number will flash up on the display. 

 

Poor Range? 

 

The No.1 cause of poor range is RX-16 location. 

  Ideally the RX-16 should be mounted in a elevated position and away from metal objects. 

  Inside a plastic box is fine, but in a metal cabinet is bad, even if the antenna is put externally. 

 

Other Wireless equipment can cause problems, watch out for wireless doorbells & garage door openers. 

  Unplug them and try again, switching to another frequency may fix the problem. 
  Cellphone towers, Radio transmitters and Power pylons can be a problem, try another frequency. 

  Adding more RX-16’s in different locations will increase your wireless coverage. 

RX-16  

RX-16  

RX-16  

Upto 300m with 0.5mm 

Upto 100m  
with 0.2mm 

RX-16’s can be Piggybacked off  
Keypads, as they both use the KP Bus 

 

FREQUENCY  

 

SW3 

SW4

 

304Mhz 

OFF 

OFF 

433Mhz 

ON 

OFF 

915Mhz 

OFF 

ON 

DIP SWITCH SETTING 

Содержание Elite S

Страница 1: ...ARROWHEAD ALARM PRODUCTS Ltd 344b Rosedale Rd Albany Auckland Ph 09 414 0085 Fax 09 414 0088 www aap co nz v1 0...

Страница 2: ...Red Detector 0v 12v EOL TAMPER EOL RELAY 2k2 TYPE 3 2k2 EOL Diagram illustrates Normally Closed N C PIR N C Alarm Contacts 2K2 Z1 8 COM N C Tamper Contacts TYPE 3 2k2 EOL Diagram illustrates Normally...

Страница 3: ...ow Zone Smoke Detector N O High Zone PIR N C Voltage Range Zone Type 15 P 125 E Z1 8 E 0 0 1 10V High Low Alarm 1 10 1 90V High Zone Alarm 1 90 2 50V Low Zone Alarm A B C E 3 30 5 00V High Low Alarm D...

Страница 4: ...40V High Low Alarm 1 40 2 30V High Zone Alarm A B C E 2 80 3 30V SEALED D 2 30 2 80V Low Zone Alarm F 3 30 5 0V High Zone Tamper Alarm Contacts N C 8K2 Z1 8 COM TYPE 14 Zone Doubling with Tampers Low...

Страница 5: ...ive Infra Red Detector 0v 12v EOL TAMPER EOL RELAY To Zone 5 Zone 1 5 4k7 8k2 Link 2k2 Alarm Contacts N C 4K7 Z1 8 COM 2K2 PIR A Tamper Contacts Alarm Contacts N C 8K2 PIR B Tamper Contacts Zone Wirin...

Страница 6: ...2 Gnd 12V 1 C 2 3 C 4 N C REED SWITCH Outputs Gnd 12V 1 2 3 4 REED 1 Zone 1 4k7 N C REED SWITCH REED 2 Zone 5 8k2 Gnd 12V 1 C 2 3 C 4 Outputs Gnd 12V 1 2 3 4 N C REED SWITCH 8k2 Zone 1 Passive Infra R...

Страница 7: ...stor must be fitted in the last detector If Multiple detectors are sharing the same zone they must be wired in a daisy chain format Smoke Detector Zone Wiring Type3 Gnd 12V 1 C 2 3 C 4 Outputs Gnd 12V...

Страница 8: ...res in the Clk terminal and check again If this gives you volts then there is a cable short somewhere or a faulty device connected If you have closer to 5volts there you might have the Data wired in b...

Страница 9: ...ce can only be learnt in once so if you try to learn the same button or PIR into a different slot the Elite S system wont let you What you can do is a search for loaded Pendants and Detectors The Prog...

Отзывы: