For examples of hitless stacking switchover operation, refer to
Hitless stacking switchover examples
on page 183.
Executing a hitless stacking switchover
The following must be in effect before a hitless switchover (to the standby controller) is allowed:
•
Hitless stacking is enabled.
•
The stack has a standby controller.
•
The standby controller has learned the protocols.
•
The standby controller has the same priority as the active controller.
•
More than 120 seconds have passed since the previous switchover or failover.
You can use the show stack command to check these criteria.
To perform a switchover, enter the following command.
device# stack switch-over
Standby unit 8 will become active controller, and unit 1 will become standby
Are you sure? (enter 'y' or 'n'): y
Unit 1 is no longer the active controller
Hitless stacking switchover examples
The following examples illustrate hitless stacking failover and switchover operation during a CLI-driven switchover or priority
change.
The following figure illustrates a hitless stacking switchover triggered by the stack switch-over command.
Hitless Stacking
Hitless stacking switchover
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01
183
Содержание ICX 7650-48P
Страница 8: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 8 Part Number 53 1005572 01...
Страница 22: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 22 Part Number 53 1005572 01...
Страница 88: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 88 Part Number 53 1005572 01...
Страница 170: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 170 Part Number 53 1005572 01...
Страница 236: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 236 Part Number 53 1005572 01...