Power
18
You can hard-wire the ARRI L5 to a building electrical installa-
tion. You can install a power plug that is suitable for the local
power outlets on the power cable. Socket outlets or external
power switches that supply the product with power must be lo-
cated near the product and easily accessible so that the prod-
uct can easily be disconnected from power.
The ARRI L5 requires a power input cable with a Neutrik
®
PowerCON
®
True1 NAC3FX-W cable connector. Cable
requirements are listed in chapter “Specifications” on page 48.
ARRI offers power cables with PowerCON
®
cable connectors
and different plugs or bare ends (see “Accessories” on
page 49).
To insert and remove the PowerCON
®
cable connector
• Line up the raised key of the connector and the keyway of the
input socket. Insert the cable connector without force in the
power input socket.
To lock the cable connector:
• Turn it a full quarter-turn clockwise.
To unlock the cable connector:
• Push the connector lock backwards and turn the cable con-
nector counter-clockwise. Pull the cable connector out of the
power input socket.
To use a battery pack
The ARRI L5 can be powered independently from AC power
with a battery pack.
The battery pack must meet the following requirements:
The product has a 4-pin XLR male connector for battery power
and DMX data input. The pin-out is:
IMPORTANT! Check that the pin-out of the battery
pack matches the pin-out of the product. Wrong
assigned pin-outs damage the ARRI L5 and / or the
battery pack.
Always follow the safety information for the battery pack. Use
only battery packs that meet all requirements listed above. The
use of battery packs that do not fulfill the requirements damage
the product and / or the battery pack.
Note: The ARRI L5 switches off when the battery voltage drops
below 22 V=. The product will be damaged, when the battery
voltage exceeds 45 V=.
Output voltage
23 - 36 V=
Battery operating temperature
68° F - 113° F
Minimum capacity
5,5 Ah
Power outlet connector
4-pin XLR connector
Pin
Assignment
1
0 V
2
Data -
3
Data +
4
+ 23 V - 36 V=
Содержание L5