SAFETY INSTRUCTIONS 

 

 

WARNING

 

 

 
Always follow the precautions listed below to avoid any possibility of serious injury or even death from electrical shock, short-
circuiting, damages, fire or other hazards. These precautions include, but are not limited to, the following:

 

 

 

Do not expose the instrument to liquids and rain. Do not use it near water or in damp or wet conditions, or place 
containers on it containing liquids. If any liquid seeps turn off the power and unplug the power cord from the AC outlet. 

 

Do not put burning items, such as candles, on the unit. A burning item may fall over and cause a fire.  

 

This instrument contains no user-serviceable parts. Do not open the instrument or attempt to disassemble or modify the 
internal circuit. 

 

Never insert or remove an electric plug with wet hands. 

 

Check the electric plug periodically and remove any dirt or dust which may have accumulated on it. 

 

Do not place the power cord near heat sources such as heaters or radiators, and do not excessively bend or otherwise 
damage the cord, place heavy objects on it, or place it in a position where anyone could walk on, trip over, or roll 
anything over it. 

 

CAUTION

 

 

 
Always follow the precautions listed below to avoid any possibility of serious injury or even death from electrical shock, short-
circuiting, damages, fire or other hazards. These precautions include, but are not limited to, the following:

 

 

 

Do not connect the instrument to an electrical outlet using a multiple-connector. Doing so can result in lower sound quality, or 
possibly cause overheating in the outlet itself. 

 

When removing the electric plug from the instrument or an outlet, hold the plug itself and not the cord. Pulling by the cord can 
damage it. 

 

Remove the electric plug from the outlet when the instrument is not to be used for extended periods of time, or during 
electrical storms. 

 

Do not place the instrument in an unstable position where it might accidentally fall over. 

 

Before moving the instrument, remove all connected cables. 

 

When setting up the product, make sure that the AC outlet you are using is easily accessible. If some trouble or malfunction 
occurs, immediately turn off the power switch and disconnect the plug from the outlet. Even when the power switch is turned 
off, electricity is still flowing to the product at the minimum level.  

 

When you are not using the product for a long time, make sure to unplug the power cord from the wall AC outlet. 

 

Use only the stand/rack specified for the instrument. When attaching the stand or rack, use the provided screws only. Failure 
to do so could cause damage to the internal components or result in the instrument falling over. 

 

Information for Users on Collection and Disposal of Old Equipment 

 

This special symbol on the products, packaging, and/or accompanying documents means that used electrical and electronic products 
should not be mixed with general household waste. 
For proper treatment, recovery and recycling of old products, please take them to applicable collection points, in accordance with your 
national legislation and the Directives 2002/96/EC. 
By disposing of these products correctly, you will help to save valuable resources and prevent any potential negative effects on human 
health and the environment which could otherwise arise from inappropriate waste handling. 
For more information about collection and recycling of old products, please contact your local municipality, your waste disposal service 
or the point of sale where you purchased the items. 

[For business users in the European Union] 

If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information. 

[Information on Disposal in other Countries outside the European Union] 

This symbol is only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and 
ask for the correct method of disposal.

 

Содержание R-506

Страница 1: ...ual Issue 0 1 REAL Innovation R 506 AUDIO SINGLE Fx10 Hz X OVER SIDE LO CUT GR VU DUAL ON OFF 20 12 12 0 0 1 1 5 0 20 20 300 200 500 400 100 150 S S S S MODE ATT ATT REL THR THR RATIO RATIO REL F F F...

Страница 2: ...trical storms Do not place the instrument in an unstable position where it might accidentally fall over Before moving the instrument remove all connected cables When setting up the product make sure t...

Страница 3: ...stems and related documentation In any case we reserve the right to change the specifications without notice but in the respect to the current legislation Disclaimer The information contained in this...

Страница 4: ...REL EASE SWITCH HI AND LO BAND 7 ATT ACK SWITCH HI AND LO BAND 8 OFF ON x10 SWITCH 8 CROSSOVER FREQUENCY KNOB 8 LINK JACK 3 5 mm STEREO jack 8 SIDE JACK 3 5 mm stereo jack 8 True BY pass ON switch LED...

Страница 5: ...I Compression LO output level Side Chain External input Side chain stereo link input True by pass function The R 506 provides four operative modes 1 Single band compressor full band on the envelope de...

Страница 6: ...enclosure Be sure that the rear edge connector on the R 506 module mates correctly with the edge connector of the 500 series enclosure Replace the 2 fastening screws through the top bottom holes in t...

Страница 7: ...sualize the compression factor on the LO channel Select VU to visualize the level at the output of the compressor When the compressor is bypassed the VU meter is able to measure the input signal level...

Страница 8: ...JACK The link Jack is used to link two R 506 units In this way two R 506 can be linked for stereo compression The left channel in the first unit is sent via the link cable to the second unit right ch...

Страница 9: ...n be user defined by an internal dip switch Four possibilities are provided DP1 DP2 Function OFF OFF The side chain are controlled by the corresponding crossover output ON OFF The LO side chain is con...

Страница 10: ...in section of the compressor can be controlled by an external signal In this way the user can build the side chain signal by using external units for example a multiband equalizer controlled by the sa...

Страница 11: ...X A Front Panel FIG 1 R 506 Front Panel R 506 AUDIO SINGLE Fx10 Hz X OVER SIDE LO CUT GR VU DUAL ON OFF 20 12 12 0 0 1 1 5 0 20 20 300 200 500 400 100 150 S S S S MODE ATT ATT REL THR THR RATIO RATIO...

Страница 12: ...k panel On the back panel 1 1 2 2 3 3 1 Ground 1 Ground 2 PHASE 2 PHASE 3 PHASE 3 PHASE disconnect pin 3 Unbalanced line Balanced line only To use unbalanced lines Unbalanced line Balanced line Can be...

Страница 13: ...06 User Manual Issue 0 1 Page 13 APPENDIX C 500 series module edge connector FIG 3 500 Series module edge connector OUT IN IN 16 V 16 V 48 V GROUND GROUND 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 GROUND OU...

Страница 14: ...HI and LO three positions slow mid fast Mode switch dual band mono band dry mono band with side chain controlled by a variable cut off frequency LO cut filter Crossover frequency Metering selection s...

Страница 15: ...ARREL Audio R 506 User Manual Issue 0 1 Page 15...