Multifunction LCD Digital Counter
Operation (Dual Counter)
Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed.
It is possible to specify a set value for which output turns ON when the set value matches the added or
subtracted result.
OUT1 and OUT2 turn ON and OFF simultaneously.
Dual Count Calculating Mode = ADD
Dual count value = CP1 PV + CP2 PV
Dual Count Calculating Mode = SUB
Dual count value = CP1 PV -CP2 PV
Note: the above is for when the output mode is N.
Note: the above is for when the output mode is K-2. SUB
mode can be used only when K-2, D,L or H is
selected as the output mode with 6-digit models.
the operation after count completion for the dual counter value is determined by the output mode.
the CP1 present value is reset when reset 1 input is turned ON and the CP2 present value is reset when reset 2
input is turned ON.
if the reset key is pressed while the dual count value, CP1 present value or CP2 present value is displayed, all of
the present values are reset and outputs turn OFF. At this time, counting is not possible for CP1 or CP2 input.
◆
◆
◆
Note:
Counting is not possible for CP1 during reset 1 input. CP2 will not be affected. The dual count value will
be calculated based on a CP1 present value of 0.
Counting is not possible for CP2 during reset 2 input. CP1 will not be affected. The dual count value will
be calculated based on a CP2 present value of 0.
The counting range for dual count value is -99,999 to 999,999.
Reset Function List
Function
1-stage/2-
stage
counter
Total counter
Batch counter
Dual counter
Screen
displayed in
run mode
Present
value/set
value(1,2)
Present
value/set
value
Total count
value
Present
value/set
value
Batch count
value/ batch
count set
value
Dual count
value/dual
count set
value
CP1 present
value/ CP2
present
value
Reset/reset
1
Present
value and
output reset
Present value and output
reset
Present value and output
reset
Only the CP1 present
value is reset
Total reset/
reset 2
No effect
Only the total count value
is reset
Batch count value and
batch output reset.
Only the CP2 present
value is reset
Reset key
Present
value and
output reset
Present
value and
output reset
Present
value, total
count value,
and output
reset
Present
value and
output reset
Present
value, batch
count value,
output and
batch output
reset.
CP1 present value, CP2
present value, dual count
value, and output reset.
■
1.
2.
1.
2.
3.
■