Aros NetMan 204 Solar Скачать руководство пользователя страница 4

 

Micro-USB port 

NetMan 204 Solar doesn’t currently use the Micro-USB port. 
 

Serial port 

NetMan 204 Solar makes available a serial communication port to which you can 
connect a RS-485/Modbus power meter for special functions. 
 

Led 

This led describes the status of 

NetMan 204 Solar

 

x

  SOLID RED: 

NetMan 204

 Solar is not communicating with the inverter. 

x

  FLASHING RED: the board is currently updating software. 

x

  OFF: regular working. 

 

Reset button 

The reset button allows to reboot the 

NetMan 204 Solar. 

 

To  reset

 

NetMan  204  Solar

:  keep  press  the  reset  button  until  the  red  led  start 

flashing (ca. 2 seconds) and then release it. 
 

U

SERS

 

It is possible to access to 

NetMan 204

 Solar with the following users: 

 

Username  Default password

 

Privileges 

ftpuser 

arosftp 

This is the ftp user that can access the log files 
(see SirioDataControl software) 

 

 

 

 

 

INSTALLATION 

x

  Remove the cover of the inverter expansion slot by removing the two retaining 

screws. 

x

  Insert 

NetMan 204 Solar 

in the slot. 

x

  Secure 

Netman 204

 Solar to the slot using the two screws removed previously. 

 
 

J

UMPER SETTING

 

 

 

Jumper JP4 have to be open only when NetMan 204 Solar is installed in 
SIRIO EVO 10000 (p/n 6PVE10KA) and SIRIO EVO 12500 (p/n 
6PVE12KA); for all the others models, JP4 has to be closed. 

 

 

JUMPER SETTING for SIRIO EVO 10000 and SIRIO EVO 12500 

 
 

 

JUMPER SETTING for all the other models 

 

 

 

CONFIGURATION 

NetMan 204

 Solar can be configured using 

SirioDataControl

 software; this 

software can be downloaded from

 www.aros-solar.com

 

 

NetMan 204

 Solar comes provided as factory default with the following 

network configuration: 
 

IP address: 192.168.1.200 

Netmask:    255.255.255.0 

Gateway:    192.168.1.254 

 

 

NetMan 204

 needs approximately 1 minute to become operational from 

when it is powered up or after a reboot; before this time the device may 
not be configurable

.

 

 
In  order  to  change  the  configuration  of

  NetMan  204  Solar

,  please  verify  that  the 

Netman 204 Solar is connected to a network and

 

run the SirioDataControl software 

on a Pc or Mac on the same network. Please refer to the complete user manual. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

The complete user manual can be downloaded from: 

 

http://www.aros-solar.com

 

 

 
 
 
 

0MNPVXXXXXXX 