TERMINAL MODE 

 

From the Configuration Screen, pressing the                 button allows for accessing the Terminal 

 

Mode in which the user can set the inverter with the various operating modes and parameters 
required by the regulations in force in the country of installation. For configuring the device correctly, 
refer to the relevant documentation IT2029, available on the website   

http://www.aros-solar.com

 

 
 
 

SERVICE 

 
The Configuration Screen contains the                 button reserved for personnel of the 

 

AROS Solar Technology Technical Assistance Service. 
Pressing this button allows for accessing various functions of the service protected by password. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
From the same screen it is possible to recalibrate the touch-screen; to perform this operation, 

 

press the                button then press the tick symbol                to confirm : a guided procedure will 

 

start that allows for recalibrating the screen; follow the instructions appearing on the display. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание 12k55enua

Страница 1: ......

Страница 2: ...RPS SpA via Somalia 20 20032 Cormano MI Tel 39 02 66327 1 Fax 39 02 66327 231 www aros solar com...

Страница 3: ...ew 4 Basic interactions 7 Description of the Menu 8 Measurements 8 Historical data 11 Configuration 15 Alarms and statuses 28 Actions 29 Information 30 TECHNICAL DETAILS 32 Technical specifications 32...

Страница 4: ...2...

Страница 5: ...3 PRESENTATION 1 Touch screen 2 USB port 3 Ethernet port 1 2 3...

Страница 6: ...erter Everything can be done with just a touch When the inverter is started up for the first time after commissioning a screen appears asking you choose the country where the inverter is installed Pre...

Страница 7: ...eft to right 2 The daily graph showing the power delivered is shown in the middle of the screen The horizontal scale represents the hours from 5 to 22 i e 5 am to 10 pm while the vertical scale repres...

Страница 8: ...stem configuration Page 15 Inverter statuses and alarms Page 30 Inverter actions Page 29 Information Page 30 Note that on the main screen touching the graph area of the screen displays the energy prod...

Страница 9: ...touching the button or specific area of the screen Swipe moving your finger on the screen while holding it down from right to left or from left to right This may be required to navigate through the da...

Страница 10: ...evice measurements The two buttons on the right hand side allow you to view the temperatures measured inside the inverter and the measurements of the four analogue probes if connected By pressing the...

Страница 11: ...ile input 4 has a rated current of 140 A the relevant settings are 1 100 2 100 3 100 5 100 6 100 7 100 8 100 4 140 180 100 77 7 78 See the next screen Press the key to access the following screen wher...

Страница 12: ...10 By pressing the analogue probes accesses the following screen The button is used to return to previous windows this button is available in all windows...

Страница 13: ...view the logs press the button with the symbol Then select the measurements to be displayed only two measures can be displayed at the same time To select a measurement press the corresponding button...

Страница 14: ...om The horizontal axis is always temporal in the time range 5 22 The vertical axis on the left has the left hand unit of measurement and the one on the right has the right hand unit of measurement The...

Страница 15: ...finished press the button with the symbol in order to safely remove the USB flash drive Note that over time the historical data takes up the device memory The button allows you to manage the archives...

Страница 16: ...ollows follow the instructions to start downloading the system card logs To cancel the operation go back to the previous screen Or press to cancel the operation and return to the previous screen At th...

Страница 17: ...r settings advanced settings access to the terminal mode for low level interactions with the inverter Service section protected by password e mail configuration section this screen allows for setting...

Страница 18: ...larm sound changes if an operator interacts with the interface After 20 minutes of inactivity if an alarm is still active the sound will go back to the initial one The button allows to set Date and Ti...

Страница 19: ...other In the same window we see that for each serial port it is possible to specify whether the addressing is dynamic or static1 this is a technical issue that regards the compatibility of communicati...

Страница 20: ...ure the individual probe The single measurement as seen can be configured in detail Description Unit of measurement Minimum value corresponding to 0 VDC input Maximum value corresponding to 10 VDC inp...

Страница 21: ...he button you can enter a percentage value which is the ratio between the photovoltaic field peak and the inverter rated power this parameter is necessary when monitoring software is used for comparin...

Страница 22: ...onfiguring the external reading for the self consumption function by means of an external multimeter via MODBUS Enable or disable the external commands MODBUS Press on the other hand to go to the netw...

Страница 23: ...lue of the UDP port used for communications via UDP on the Ethernet network e g SunVision2 monitoring software The value 33000 is pre defined it is possible to modify it and enter the desired value Th...

Страница 24: ...mail message to verify whether the settings are correct by pressing the button Lastly press the button to confirm the electronic mail configuration DNS on this page enter any DNS server addresses that...

Страница 25: ...mple it is possible to connect to the remote display from a personal computer You can configure the password which must be confirmed and the port used by the service The default password is secret Fro...

Страница 26: ...to connect other brand instruments on the 485 bus in this case an accurate reading of the manual is suggested to have the correct settings Use the and buttons to change the set of parameters Select t...

Страница 27: ...inverters In order to scan the LAN press the button this will lead the user to the screen Press the button to execute a scan of the LAN All the inverters must have the same label plant name to be fou...

Страница 28: ...lable on the website http www aros solar com SERVICE The Configuration Screen contains the button reserved for personnel of the AROS Solar Technology Technical Assistance Service Pressing this button...

Страница 29: ...the e mail configuration procedure was carried out correctly the following screen will appear Press or to enable or disable sending of a type of e mail and press to increase or decrease the delay time...

Страница 30: ...n alarm a sound will be emitted at 5 second intervals until the alarm disappears or the user touches the screen If the user touches the screen the sound will change intensity and timbre If after 20 mi...

Страница 31: ...tware updates this action does not affect inverter operation in any way The button if pressed disables the UDP slave function in the self consumption case To enable the function again hit the same but...

Страница 32: ...chine temperature and the inverter probes on power module heat sinks Presence of the built in isolation transformer The installation date Year Month Day The Euros saved The energy hour meter used can...

Страница 33: ...e status of communications In this example we see a PVSER UDP connection on the Ethernet port and and an external measure on slot 1 The green red blinking led means that on that slot is present receiv...

Страница 34: ...00 configurable MODBUS MODBUS TCP RFB protocol used by screen sharing programs such as VNC protected by configurable password The default password is secret Sunvision 2 from 2 0 5 version upwards coul...

Страница 35: ...33...

Страница 36: ...0MNPHV12K55ENUA 02...

Отзывы: