Page 8 of 8
PD10X-X-X (en)
PN 97999-1068
DIMENSIONAL DATA
Low output volume, erratic flow, or no flow.
Check air supply.
Check for plugged outlet hose.
Check for kinked (restrictive) outlet material hose.
Check for kinked (restrictive) or collapsed inlet material
hose.
Check for pump cavitation − suction pipe should be
sized at least as large as the inlet thread diameter of the
pump for proper flow if high viscosity fluids are being
pumped. Suction hose must be a non-collapsing type,
capable of pulling a high vacuum.
Check all joints on the inlet manifolds and suction con-
nections. These must be air tight.
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.
Product discharged from exhaust outlet.
Check for diaphragm rupture.
Check tightness of (14) diaphragm washer.
Air bubbles in product discharge.
Check connections of suction plumbing.
Check O” rings between intake manifold and inlet side
fluid caps.
Check tightness of (14) diaphragm washer.
Motor blows air or stalls.
Check (176) check valve for damage or wear.
Check for restrictions in valve / exhaust.
TROUBLE SHOOTING
A
Q
P
L
F
E
R
H
J
C
D
M
B
G
K
N
Air Inlet 1/4 -18 NPT
Exhaust Port 3/4 - 14 NPT
Inlet
Outlet
1 - 11-1/2 NPTF - 1 (PX10X-AXX-XXX)
1 - 11 BSP (PX10X-BXX-XXX)
-
-
(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).
A - 12-11/32” (313.2 mm) E - see below
J - 7-5/16” (185.7 mm)
N - see below
B - 11-9/16” (293.7 mm) F - see below
K - 13/32” (10.3 mm)
P - 5-27/32” (148.2 mm)
C - 4” (101.6 mm) G - 12-7/16” (315.9 mm)
L - 1-1/2” (38.1 mm)
Q - 12” (304.8 mm)
D - 1-1/4” (31.8 mm) H - 6-1/4” (158.8 mm)
M - 6-15/32” (164.3 mm)
R - see below
“E” “F”
“R”
PX10A-XXX-XXX ------
8-1/8” (206.4 mm) 14-1/32” (356.2 mm)
PX10R-XXX-XXX
11-3/32” (281.3 mm)
8-5/16” (211.1 mm)
------
PX10S-XXX-XXX ------
8-3/16” (207.9 mm) 13-27/32” (351.4 mm)
DIMENSIONS
“N”
PX10X-XAX-XXX
1/4” (6.4 mm)
PX10X-XCX-XXX
9/32” (7.1 mm)
PX10X-XHX-XXX
9/32” (7.1 mm)
PX10X-XSX-XXX
9/32” (7.1 mm)
-
-
-
-
-
-
-
Figure 4