OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

WARNING

EXCESSIVE AIR PRESSURE. Can cause person-

al injury, pump damage or property damage.

S

Do not exceed the maximum inlet air pressure as stated on the

pump model plate.

S

Be sure material hoses and other components are able to with-

stand fluid pressures developed by this pump. Check all hoses

for damage or wear. Be certain dispensing device is clean and

in proper working condition.

WARNING

STATIC SPARK. Can cause explosion resulting in

severe injury or death. Ground pump and pumping system.

S

Use the pump grounding screw terminal provided. Use ARO

part no. 66885-1 ground kit or connect a suitable ground wire

(12 ga. min.) to a good earth ground source.

S

Secure pump, connections and all contact points to avoid

vibration and generation of contact or static spark.

S

Consult local building codes and electrical codes for specific

grounding requirements.

S

Aftergrounding,periodicallyverifycontinuityofelectricalpath

to ground. Test with an ohmmeter from each component (e.g.,

hoses, pump, clamps, container, spray gun, etc.) to ground to

insure continuity. Ohmmeter should show 0.1 ohms or less.

S

Submerse the outlet hose end, dispensing valve or device in

the material being dispensed if possible. (Avoid free streaming

of material being dispensed.)

S

Use hoses incorporating a static wire.

S

Use proper ventilation.

S

Keep inflammables away from heat, open flames and sparks.

S

Keep containers closed when not in use.

WARNING

Pump exhaust may contain contaminants. Can

causesevereinjury.Pipeexhaustawayfromworkareaandper-

sonnel.

S

In the event of a diaphragm rupture, material can be forced out

of the air exhaust muffler.

S

Pipe the exhaust to a safe remote location when pumping haz-

ardous or inflammable materials.

S

Use a grounded 1” minimum i.d. hose between the pump and

the muffler.

WARNING

HAZARDOUS PRESSURE. Can result in serious

injury or property damage. Do not service or clean pump,

hoses or dispensing valve while the system is pressurized.

S

Disconnect air supply line and relieve pressure from the sys-

tem by opening dispensing valve or device and / or carefully

and slowly loosening and removing outlet hose or piping from

pump.

WARNING

HAZARDOUSMATERIALS.Cancauseseriousin-

jury or property damage. Do not attempt to return a pump to the

factory or service center that contains hazardous material.

Safe handling practices must comply with local and national

laws and safety code requirements.

S

Obtain Material Safety Data Sheets on all materials from the

supplier for proper handling instructions.

WARNING

EXPLOSION HAZARD. Models containing alumi-

num wetted parts cannot be used with III.-Trichloroethane, Me-

thylene Chloride or other Halogenated Hydrocarbon solvents

which may react and explode.

S

Check pump motor section, fluid caps, manifolds and all

wettedpartstoassurecompatibilitybeforeusingwithsolvents

of this type.

WARNING

MISAPPLICATION HAZARD. Do not use models

containing aluminum wetted parts with food products for hu-

man consumption. Plated parts can contain trace amounts of

lead.

CAUTION

Verify the chemical compatibility of the pump

wetted parts and the substance being pumped, flushed or re-

circulated. Chemical compatibility may change with tempera-

ture and concentration of the chemical(s) within the

substances being pumped, flushed or circulated. For specific

fluid compatibility, consult the chemical manufacturer.

CAUTION

Maximum temperatures are based on mechani-

cal stress only. Certain chemicals will significantly reduce

maximum safe operating temperature. Consult the chemical

manufacturer for chemical compatibility and temperature lim-

its. Refer to PUMP DATA on page 1 of this manual.

CAUTION

Be certain all operators of this equipment have

been trained for safe working practices, understand it’s limita-

tions, and wear safety goggles / equipment when required.

CAUTION

Do not use the pump for the structural support of

the piping system. Be certain the system components are

properly supported to prevent stress on the pump parts.

S

Suction and discharge connections should be flexible connec-

tions (such as hose), not rigid piped, and should be compatible

with the substance being pumped.

CAUTION

Prevent unnecessary damage to the pump. Do

notallowpumptooperatewhenoutofmaterialforlongperiods

of time.

S

Disconnect air line from pump when system sits idle for long

periods of time.

CAUTION

Use only genuine ARO replacement parts to as-

sure compatible pressure rating and longest service life.

NOTICE

Replacement warning labels are available upon

request: “Static Spark & Diaphragm Rupture” pn \ 94080.

WARNING

CAUTION

NOTICE

= Hazards or unsafe practices which could

result in severe personal injury, death or

substantial property damage.

= Hazards or unsafe practices which could

result in minor personal injury, product or

property damage.

= Important installation, operation or main-

tenance information.

 (en)

Содержание PF20R-X-B

Страница 1: ...Maximum Particle Size 2 dia 51 mm semi solids Maximum Temperature Limits diaphragm flap bumper material E P R EPDM 60_to280_F 51_to 138_C Nitrile 10_ to 180_ F 12_ to 82_ C Polyurethane 10_ to 150_ F 12_ to 66_ C SantopreneR 40_to225_F 40_to 107_C PTFE 40_ to 225_ F 4_ to 107_ C VitonR 40_to350_F 40_to 177_C Dimensional Data see page 8 Mounting Dimension 9 1 16 x 10 1 16 230 mm x 256 mm Noise Leve...

Страница 2: ... Donotattempttoreturnapumptothe factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements S Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing alumi numwettedpartscannotbeusedwith III Trichloroethane Me thylene...

Страница 3: ... KITS Refertothepartviewsanddescriptionsasprovidedonpage4through7 for parts identification and Service Kit information S Certain ARO Smart Parts are indicated which should be available for fast repair and reduction of down time S Service kits are divided to service two separate diaphragm pump functions 1 AIR SECTION 2 FLUID SECTION The FLUID SEC TION is divided further to match typical part MATERI...

Страница 4: ...X B PF20X ASX SXX B PF20X BSX SXX B N P T F B S P N P T F B S P Item Description size Qty Part No Mtl Part No Mtl Part No Mtl Part No Mtl 15 Fluid Cap 2 94359 CI 94359 CI 95560 SS 95560 SS 53 Manifold Elbow 2 94362 CI 94362 CI 95563 SS 95563 SS 60 Bottom Manifold 1 94347 1 CI 94347 2 CI 95510 1 SS 95510 2 SS 61 Top Manifold 1 94348 1 CI 94348 2 CI 95511 1 SS 95511 2 SS 63 Pipe Plug 2 11 1 2 N P T ...

Страница 5: ...66307 V PF20X XXX SVX B TORQUE REQUIREMENTS LUBRICATION SEALANTS Z Lubriplate FML 2 is a white food grade petroleum grease k Apply Lubriplate FML 2 grease to all O rings U Cups mating parts x Apply Loctite 242 to threads at assembly u Apply Loctite 503 pipe sealant 75 75 7 PTFE VIEW OF TWO PIECE PTFE DIAPHRAGM 80 u 8 6 4 1 7 5 3 2 Torque Sequence G 27 126 29 8 SANTOPRENE 55 60 61 26 G 55 175 k NOT...

Страница 6: ... from Fluid Section repair S Inspect and replace old parts with new parts as necessary Look for deep scratches on surfaces and nicks or cuts in O rings S Take precautions to prevent cutting O rings upon installation S Lubricate O rings with Lubriplate FML 2 grease S Do not over tighten fasteners refer to torque specification block on view S Re torque fasteners following restart S SERVICE TOOLS To ...

Страница 7: ...ase to O rings U Cups mating parts 136 137 k 139 k 111 138 k 105 135 133 134 101 103 174 k 121 118 173 k 169 k 172 k 171 k 170 167 k 173 121 k 174 118 166 k 132 k 243 k 244 k 199 k 141 k 140 232 k 200 k 232 k 233 176 k PILOT VALVE PART GROUP MAJOR VALVE A 637374 Replacement Major Valve Service Assembly is available separately which includes the following 105 4 107 2 111 132 135 136 137 138 139 140...

Страница 8: ...se must be a non col lapsing type capable of pulling a high vacuum S Check all joints on the inlet manifolds and suction connections These must be air tight S Inspectthepumpforsolidobjectsloggedinthediaphragmchamber or the seat area DIMENSIONAL DATA Dimensions shown are for reference only they are displayed in inches and millimeters mm Figure 4 Air Inlet 3 4 14 N P T Inlet Outlet A K Dotted lines ...