ARO PF20R-X-B Скачать руководство пользователя страница 1

CCN 15227671

 

D

INGERSOLL RAND COMPANY

209 NORTH MAIN STREET

-

BRYAN, OHIO 43506

OPERATOR’S MANUAL

PF20R-X-B

RELEASED: 12-14-04

REVISED:

9

-

15-11

(REV. 0

4

)

INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

2” DIAPHRAGM PUMP

1:1 RATIO FLAP VALVE (METALLIC)

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

SERVICE KITS

Refer to Model Description Chart to match the pump material options.

637369 for air section repair (see page 6).

637310-XX for fluid section repair (see page 3).

637374 major air valve assembly (see page 7).

PUMP DATA

Models

see Model Description Chart for “-XXX”.

. .

Pump Type

Metallic, Air Operated, Double Diaphragm, Flap Valve

Material

see Model Description Chart.

. .

Weight

PF20X-XCX-SXX-B

178.7 lbs (81.1 kgs)

. . .

. . . . .

PF20X-XSX-SXX-B

180.6 lbs (81.9 kgs)

. . . . .

Maximum Air Inlet Pressure

120 p.s.i.g. (8.3 bar)

. . . . . . . . .

Maximum Material Inlet Pressure

10 p.s.i.g. (0.69 bar)

. . . . .

Maximum Outlet Pressure

120 p.s.i.g. (8.3 bar)

. . . . . . . . . .

Maximum Flow Rate

172 g.p.m. (651 l.p.m.)

. . . . . . . . . . . . . .

Displacement / Cycle @ 100 p.s.i.g.

1.4 gal. (5.3 lit.)

. . .

Maximum Particle Size

2” dia. (51 mm) semi-solids

. . . . . . . . . . . .

Maximum Temperature Limits (diaphragm / flap / bumper material)

E.P.R. / EPDM

-60

_

to 280

_

F (-51

_

to 138

_

C)

. . . . . . . . . . .

Nitrile

10

_

to 180

_

F (-12

_

to 82

_

C)

. . . . . . . . . . . . . . . . .

Polyurethane

10

_

to 150

_

F (-12

_

to 66

_

C)

. . . . . . . . . . . .

Santoprene

R

-40

_

to 225

_

F (-40

_

to 107

_

C)

. . . . . . . . . . .

PTFE

40

_

to 225

_

F (4

_

to 107

_

C)

. . . . . . . . . . . . . . . . .

Viton

R

-40

_

to 350

_

F (-40

_

to 177

_

C)

. . . . . . . . . . . . . . . .

Dimensional Data

see page 8

. . . . . . . . . . . . . . . .

Mounting Dimension

9-1/16” x 10-1/16” (230 mm x 256 mm)

. . . . .

Noise Level

@ 70 p.s.i., 60 c.p.m.

{

85.0 db(A)

|

. . . .

{

Tested with 67263 muffler assembly installed.

|

The pump sound pressure levels published here have been updated to an Equivalent Continuous
Sound Level (L

Aeq

) to meet the intent of ANSI S1.13-1971, CAGI-PNEUROP S5.1 using four mi-

crophone locations.

Figure 1

MODEL DESCRIPTION CHART

PF20 X - X X X - S X X - B

PF20X - XXX - S X X - B

637310 - X X

Diaphragm

Flap

FLUID SECTION SERVICE KIT SELECTION

EXAMPLE: MODEL # PF20R-ACP-SAA-B

FLUID SECTION SERVICE KIT # 637310-AA

SEAT MATERIAL

S - Stainless Steel

DIAPHRAGM MATERIAL

A - Santoprene

T - PTFE / Santoprene

G - Nitrile

V - Viton

HARDWARE MATERIAL

P - Plated Steel

S - Stainless Steel

FLUID CAPS & MANIFOLD MATERIAL

C - Cast Iron

S - Stainless Steel

THREAD

A - N.P.T.F.

B - BSP

AIR MOTOR / AIR CAP MATERIAL

R - Polypropylene / Stainless Steel

Y - Polypropylene / Cast Iron

FLAP MATERIAL

A - E.P.R.

U - Polyurethane

G - Nitrile

V - Viton

(800) 495-0276  

FAX(800) 892-6276

© 201

1

 

www.ingersollrandproducts.com 

Содержание PF20R-X-B

Страница 1: ...Maximum Particle Size 2 dia 51 mm semi solids Maximum Temperature Limits diaphragm flap bumper material E P R EPDM 60_to280_F 51_to 138_C Nitrile 10_ to 180_ F 12_ to 82_ C Polyurethane 10_ to 150_ F 12_ to 66_ C SantopreneR 40_to225_F 40_to 107_C PTFE 40_ to 225_ F 4_ to 107_ C VitonR 40_to350_F 40_to 177_C Dimensional Data see page 8 Mounting Dimension 9 1 16 x 10 1 16 230 mm x 256 mm Noise Leve...

Страница 2: ... Donotattempttoreturnapumptothe factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements S Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing alumi numwettedpartscannotbeusedwith III Trichloroethane Me thylene...

Страница 3: ... KITS Refertothepartviewsanddescriptionsasprovidedonpage4through7 for parts identification and Service Kit information S Certain ARO Smart Parts are indicated which should be available for fast repair and reduction of down time S Service kits are divided to service two separate diaphragm pump functions 1 AIR SECTION 2 FLUID SECTION The FLUID SEC TION is divided further to match typical part MATERI...

Страница 4: ...X B PF20X ASX SXX B PF20X BSX SXX B N P T F B S P N P T F B S P Item Description size Qty Part No Mtl Part No Mtl Part No Mtl Part No Mtl 15 Fluid Cap 2 94359 CI 94359 CI 95560 SS 95560 SS 53 Manifold Elbow 2 94362 CI 94362 CI 95563 SS 95563 SS 60 Bottom Manifold 1 94347 1 CI 94347 2 CI 95510 1 SS 95510 2 SS 61 Top Manifold 1 94348 1 CI 94348 2 CI 95511 1 SS 95511 2 SS 63 Pipe Plug 2 11 1 2 N P T ...

Страница 5: ...66307 V PF20X XXX SVX B TORQUE REQUIREMENTS LUBRICATION SEALANTS Z Lubriplate FML 2 is a white food grade petroleum grease k Apply Lubriplate FML 2 grease to all O rings U Cups mating parts x Apply Loctite 242 to threads at assembly u Apply Loctite 503 pipe sealant 75 75 7 PTFE VIEW OF TWO PIECE PTFE DIAPHRAGM 80 u 8 6 4 1 7 5 3 2 Torque Sequence G 27 126 29 8 SANTOPRENE 55 60 61 26 G 55 175 k NOT...

Страница 6: ... from Fluid Section repair S Inspect and replace old parts with new parts as necessary Look for deep scratches on surfaces and nicks or cuts in O rings S Take precautions to prevent cutting O rings upon installation S Lubricate O rings with Lubriplate FML 2 grease S Do not over tighten fasteners refer to torque specification block on view S Re torque fasteners following restart S SERVICE TOOLS To ...

Страница 7: ...ase to O rings U Cups mating parts 136 137 k 139 k 111 138 k 105 135 133 134 101 103 174 k 121 118 173 k 169 k 172 k 171 k 170 167 k 173 121 k 174 118 166 k 132 k 243 k 244 k 199 k 141 k 140 232 k 200 k 232 k 233 176 k PILOT VALVE PART GROUP MAJOR VALVE A 637374 Replacement Major Valve Service Assembly is available separately which includes the following 105 4 107 2 111 132 135 136 137 138 139 140...

Страница 8: ...se must be a non col lapsing type capable of pulling a high vacuum S Check all joints on the inlet manifolds and suction connections These must be air tight S Inspectthepumpforsolidobjectsloggedinthediaphragmchamber or the seat area DIMENSIONAL DATA Dimensions shown are for reference only they are displayed in inches and millimeters mm Figure 4 Air Inlet 3 4 14 N P T Inlet Outlet A K Dotted lines ...

Отзывы: