ARO PD20 series Скачать руководство пользователя страница 4

Page 4 of 12 

PX20X-XXX-XXX-BXXX (en)

y

 Hytrel®, and Viton® are registered trademarks of the DuPont Company 

y

 Loctite® is a registered trademark of Henkel Loctite Corporation 

y

 Kynar® is a registered trademark of Arkema Inc. 

y

y

 Santoprene® is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. 

y

 ARO® is a registered trademark of Ingersoll-Rand Company 

y

y

 Lubriplate® is a registered trademark of Lubriplate Division (Fiske Brothers Refining Company) 

y

 262™, 271™ and 572™ are trademarks of Henkel Loctite Corporation 

y

GENERAL DESCRIPTION

The ARO diaphragm pump offers high volume delivery even 

at low air pressure and a broad range of material compatibili-

ty options are available. Refer to the model and option chart. 

ARO pumps feature stall resistant design, modular air motor / 

fluid sections.

Air operated double diaphragm pumps utilize a pressure dif-

ferential in the air chambers to alternately create suction and 

a positive fluid pressure in the fluid chambers, valve checks 

insure a positive flow of fluid.

Pump cycling will begin as air pressure is applied and will 

continue to pump and keep up with the demand. It will build 

and maintain line pressure and will stop cycling once maxi-

mum line pressure is reached (dispensing device closed) and 

will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

 EXCESSIVE AIR PRESSURE. Can cause pump 

damage, personal injury or property damage.

 

y

A filter capable of filtering out particles larger than 50 

microns should be used on the air supply. There is no lu-

brication required other than the “O” ring lubricant which 

is applied during assembly or repair.

 

y

If lubricated air is present, make sure that it is compatible 

with the “O” rings and seals in the air motor section of the 

pump.

OPERATING INSTRUCTIONS

 

y

Always flush the pump with a solvent compatible with 

the material being pumped if the material being pumped 

is subject to “setting up” when not in use for a period of 

time.

 

y

Disconnect the air supply from the pump if it is to be in-

active for a few hours.

 

y

The outlet material volume is governed not only by the air 

supply, but also by the material supply available at the in-

let. The material supply tubing should not be too small or 

restrictive. Be sure not to use hose which might collapse.

 

y

When the diaphragm pump is used in a forced-feed 

(flooded inlet) situation, it is recommended that a “check 

valve” be installed at the air inlet.

 

y

Secure the diaphragm pump legs to a suitable surface to 

insure against damage by vibration.

PARTS AND SERVICE KITS

Refer to the part views and descriptions as provided on pages 

5 through 8 for parts identification and service kit informa-

tion.

 

y

Certain ARO “Smart Parts” are indicated which should be 

available for fast repair and reduction of down time.

 

y

Service kits are divided to service two separate diaphragm 

pump functions: 1. AIR SECTION, 2. FLUID SECTION. The 

Fluid Section is divided further to match typical part Ma-

terial Options.

MAINTENANCE

 

y

Provide a clean work surface to protect sensitive internal 

moving parts from contamination from dirt and foreign 

matter during service disassembly and reassembly.

 

y

Keep good records of service activity and include the 

pump in preventive maintenance program.

 

y

Before disassembling, empty captured material in the 

outlet manifold by turning the pump upside down to 

drain material from the pump.

FLUID SECTION DISASSEMBLY

1.  Remove (61) outlet manifold and (60) inlet manifold.

2.  Remove (22) balls, (19) “O” rings (if applicable) and (21) 

seats.

3.  Remove (15) fluid caps.

NOTE: Only PTFE diaphragm models use a primary dia-

phragm (7) and a backup diaphragm (8). Refer to the auxiliary 

view in the Fluid Section illustration.

4.  Remove the (6) diaphragm washer, (7) or 7 / 8) dia-

phragms and (5) backup washer.

NOTE: Do not scratch or mar the surface of (1) diaphragm 

rod.

FLUID SECTION REASSEMBLY

SERVICE NOTE: ARO pn 204214-T diaphragm assembly tool 

is recommended for use when reassembling the pump.

 

y

Reassemble in reverse order. Refer to the torque require-

ments on page 6.

 

y

Clean and inspect all parts. Replace worn or damaged 

parts with new parts as required.

 

y

Lubricate (1) diaphragm rod and (144) “U” cups with Lubri-

plate® FML-2 grease (94276 grease packet is included in 

service kit).

 

y

For models with PTFE diaphragms: Item (8) Santoprene 

diaphragm is installed with the side marked “AIR SIDE” 

towards the pump center body. Install the (7) PTFE dia-

phragm with the side marked “FLUID SIDE” towards the 

(15) fluid cap.

 

y

Re-check torque settings after the pump has been 

re-started and run a while.

Содержание PD20 series

Страница 1: ...ription Chart Weight PX20A XAX XXX BXXX 91 4 lbs 41 5 kgs PX20A XCX XXX BXXX 147 4 lbs 66 9 kgs PX20A AHX XXX BXXX BHX 155 0 lbs 70 3 kgs PX20A ASX XXX BXXX BSX 149 8 lbs 68 0 kgs PX20A FHX XXX BXXX 169 4 lbs 76 8 kgs PX20A FSX XXX BXXX 162 0 lbs 73 5 kgs add 28 9 lbs 13 1 kg for stainless steel air motor section Maximum Air Inlet Pressure 120 psig 8 3 bar Maximum Material Inlet Pressure 10 psig 0...

Страница 2: ...ctory if you have questions concerning availability G End of Stroke ATEX IECEx NEC CEC F End of Stroke feedback E End of Stroke feedback Leak Detection R End of Stroke NEC Special Testing For Special Testing options please contact your nearest Ingersoll Rand Customer Service Representative or Distributor H End of Stroke Leak Detection ATEX IECEx NEC CEC L Leak Detection M Leak Detection ATEX IECEx...

Страница 3: ...ty damage Do not attempt to return a pump to the factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements y y Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing aluminum parts cannot be used with 1 1 1 trichlo...

Страница 4: ...ial supply tubing should not be too small or restrictive Be sure not to use hose which might collapse y y When the diaphragm pump is used in a forced feed flooded inlet situation it is recommended that a check valve be installed at the air inlet y y Secure the diaphragm pump legs to a suitable surface to insure against damage by vibration PARTS AND SERVICE KITS Refer to the part views and descript...

Страница 5: ...p 94356 4 E XXB 637309 XXB 637309 XB 94330 A 2 Sp 94356 4 E XXC 637309 XXC 637309 XC 94329 C 2 H Y327 237 4 V XXG 637309 XXG 637309 XG 96330 2 2 B Y325 237 4 B XXL 637309 XXL 637309 XL 94355 L 2 L 94330 A 2 SP Y328 237 4 T XXM 637309 XXM 637309 XM 94329 M 2 MSP Y328 237 4 T XXT 637309 XXT 637309 XT 94355 T 2 T 94330 A 2 SP Y328 237 4 T XXV 637309 XXV 637309 XV 95344 2 V Y327 237 4 V CENTER SECTION...

Страница 6: ...eads and bolt and nut flange heads which contact pump case when using stainless steel fasteners Apply Loctite 262 to threads at assembly Apply Loctite 572 to threads Note Lubriplate FML 2 is a white food grade petroleum grease Dash 131 Screw 35 40 ft lbs 47 5 54 2 Nm Not used with PX20X XXX AXX B CXX and GXX Not used with PX20X XXX XXX B0L Apply PTFE tape to threads 1 22 19 21 22 19 21 60 69 29 70...

Страница 7: ...BXXX only AIR MOTOR SECTION SERVICE Service is divided into two parts 1 Pilot Valve 2 Major Valve GENERAL REASSEMBLY NOTES y y Air Motor Section service is continued from Fluid Section repair y y Inspect and replace old parts with new parts as neces sary Look for deep scratches on metallic surfaces and nicks or cuts in O rings y y Take precautions to prevent cutting O rings upon instal lation y y ...

Страница 8: ...X XXX BXXX 105 4 111 128 2 132 133 3 134 4 135 136 137 138 139 140 141 146 147 176 2 199 200 233 240 2 241 242 243 and 244 637374 5 for models PE20S XXX XXX BXXX 76 105 4 111 128 2 132 133 3 134 4 135 136 137 138 139 140 141 146 147 176 2 199 200 233 240 2 241 242 243 and 244 105 Screw 40 50 in Lbs 4 5 5 6 Nm 134 Screw 40 50 in Lbs 4 5 5 6 Nm 240 Screw 40 50 in Lbs 4 5 5 6 Nm Apply anti seize comp...

Страница 9: ...Exhaust port 1 1 2 11 1 2 N P T S Material inlet PX20X FXX XXX BXXX Material inlet PX20X AXX XXX BXXX T PX20X BXX XXX BXXX U Material outet PX20X AXX XXX BXXX T PX20X BXX XXX BXXX U S Material outlet PX20X FXX XXX BXXX Dotted lines show optional 67263 muffler assembly DIMENSIONS A see below B 24 3 4 628 7 mm C 10 1 16 255 6 mm D see below E 16 3 16 411 2 mm F 12 304 8 mm G 26 1 4 666 8 mm H 9 1 16...

Страница 10: ...Page 10 of 12 PX20X XXX XXX BXXX en ...

Страница 11: ...PX20X XXX XXX BXXX en Page 11 of 12 ...

Страница 12: ...Page 12 of 12 PX20X XXX XXX BXXX en PN 97999 1108 ...