ARO ARO PD15P-X Скачать руководство пользователя страница 2

PD15P-X

Page 2 of 8

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

EXCESSIVE AIR PRESSURE
STATIC SPARK

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE

WARNING

EXCESSIVE AIR PRESSURE. Can cause person-

al injury, pump damage or property damage.

S

Do not exceed the maximum inlet air pressure as stated on the
pump model plate.

S

Be sure material hoses and other components are able to with-
stand fluid pressures developed by this pump. Check all hoses
for damage or wear. Be certain dispensing device is clean and
in proper working condition.

WARNING

STATIC SPARK. Can cause explosion resulting in

severe injury or death. Ground pump and pumping system.

S

Sparks can ignite flammable material and vapors.

S

The pumping system and object being sprayed must be
grounded when it is pumping, flushing, recirculating or spray-
ing flammable materials such as paints, solvents, lacquers,
etc. or used in a location where surrounding atmosphere is
conducive to spontaneous combustion. Ground the dispens-
ing valve or device, containers, hoses and any object to which
material is being pumped.

S

Secure pump, connections and all contact points to avoid
vibration and generation of contact or static spark.

S

Consult local building codes and electrical codes for specific
grounding requirements.

S

After grounding, periodically verify continuity of electrical path
to ground. Test with an ohmmeter from each component (e.g.,
hoses, pump, clamps, container, spray gun, etc.) to ground to
insure continuity. Ohmmeter should show 0.1 ohms or less.

S

Submerse the outlet hose end, dispensing valve or device in
the material being dispensed if possible. (Avoid free streaming
of material being dispensed.)

S

Use hoses incorporating a static wire.

S

Use proper ventilation.

S

Keep inflammables away from heat, open flames and sparks.

S

Keep containers closed when not in use.

WARNING

Pump exhaust may contain contaminants. Can

cause severe injury. Pipe exhaust away from work area and per-
sonnel.

S

In the event of a diaphragm rupture, material can be forced out
of the air exhaust muffler.

S

Pipe the exhaust to a safe remote location when pumping haz-
ardous or inflammable materials.

S

Use a grounded 3/4” minimum i.d. hose between the pump and
the muffler.

WARNING

HAZARDOUS PRESSURE. Can result in serious

injury or property damage. Do not service or clean pump,
hoses or dispensing valve while the system is pressurized.

S

Disconnect air supply line and relieve pressure from the sys-
tem by opening dispensing valve or device and / or carefully
and slowly loosening and removing outlet hose or piping from
pump.

WARNING

HAZARDOUS MATERIALS. Can cause serious in-

jury or property damage. Do not attempt to return a pump to the
factory or service center that contains hazardous material.
Safe handling practices must comply with local and national
laws and safety code requirements.

S

Obtain Material Safety Data Sheets on all materials from the
supplier for proper handling instructions.

WARNING

EXPLOSION HAZARD. Models containing alumi-

num wetted parts cannot be used with III.-Trichloroethane, Me-
thylene Chloride or other Halogenated Hydrocarbon solvents
which may react and explode.

S

Check pump motor section, fluid caps, manifolds and all
wetted parts to assure compatibility before using with solvents
of this type.

WARNING

MISAPPLICATION HAZARD. Do not use models

containing aluminum wetted parts with food products for hu-
man consumption. Plated parts can contain trace amounts of
lead.

CAUTION

Verify the chemical compatibility of the pump

wetted parts and the substance being pumped, flushed or re-
circulated. Chemical compatibility may change with tempera-
ture and concentration of the chemical(s) within the
substances being pumped, flushed or circulated. For specific
fluid compatibility, consult the chemical manufacturer.

CAUTION

Maximum temperatures are based on mechani-

cal stress only. Certain chemicals will significantly reduce
maximum safe operating temperature. Consult the chemical
manufacturer for chemical compatibility and temperature lim-
its. Refer to PUMP DATA on page 1 of this manual.

CAUTION

Be certain all operators of this equipment have

been trained for safe working practices, understand it’s limita-
tions, and wear safety goggles / equipment when required.

CAUTION

Do not use the pump for the structural support of

the piping system. Be certain the system components are
properly supported to prevent stress on the pump parts.

S

Suction and discharge connections should be flexible connec-
tions (such as hose), not rigid piped, and should be compatible
with the substance being pumped.

CAUTION

Prevent unnecessary damage to the pump. Do

not allow pump to operate when out of material for long periods
of time.

S

Disconnect air line from pump when system sits idle for long
periods of time.

CAUTION

Use only genuine ARO replacement parts to as-

sure compatible pressure rating and longest service life.

NOTICE

RE-TORQUE ALL FASTENERS BEFORE OPERA-

TION. Creep of housing and gasket materials may cause fas-
teners to loosen. Re-torque all fasteners to insure against fluid
or air leakage.

WARNING

CAUTION

NOTICE

= Hazards or unsafe practices which could

result in severe personal injury, death or
substantial property damage.

= Hazards or unsafe practices which could

result in minor personal injury, product
or property damage.

= Important installation, operation or

maintenance information.

Содержание ARO PD15P-X

Страница 1: ...l material E P R EPDM 60_to280_F 51_to 138_C HytrelR 20_ to 150_ F 29_ to 66_ C Nitrile 10_ to 180_ F 12_ to 82_ C Polypropylene 35_ to 175_ F 2_ to 79_ C PVDF KynarR 10_ to 200_ F 12_ to 93_ C SantopreneR 40_to225_F 40_to 107_C PTFE 40_ to 225_ F 4_ to 107_ C VitonR 40_to350_F 40_to 177_C Dimensional Data see page 8 Mounting Dimension 8 687 x 14 937 220 7 mm x 379 4 mm Noise Level 70 p s i 60 c p...

Страница 2: ...tlet hose or piping from pump WARNING HAZARDOUSMATERIALS Cancauseseriousin juryorpropertydamage Donotattempttoreturnapumptothe factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements S Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSI...

Страница 3: ...ded S Flooded suction inlet pressure must not exceed 10 p s i g 0 69 bar OPERATING INSTRUCTIONS S Always flush the pump with a solvent compatible with the material beingpumpedifthematerialbeingpumpedissubjectto settingup when not in use for a period of time S Disconnecttheairsupplyfromthepumpifitistobeinactiveforafew hours PARTS AND SERVICE KITS Refertothepartviewsanddescriptionsasprovidedonpage4t...

Страница 4: ... E XXT 637391 XT 96165 T 2 T 96164 A 2 SP 96057 4 T 95910 4 T XXV 637391 XV 95820 3 2 V Y327 336 4 V Y327 342 4 V MANIFOLD FLUID CAP MATERIAL OPTIONS PX15P XXS XXX PVDF Kynar Polypropylene PX15P FKS XXX PX15P YKS XXX PX15P FPS XXX PX15P YPS XXX Item Description size Qty Part No Mtl Part No Mtl Part No Mtl Part No Mtl 6 Diaphragm Washer 2 95975 2 K 95975 2 K 95975 1 P 95975 1 P 15 Fluid Cap 2 95972...

Страница 5: ...FML 2 grease to all O rings U Cups mating parts x Apply LoctiteR 242 to threads at assembly U Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners Z Lubriplate FML 2 is a white food grade petroleum grease DIAPHRAGM BALL MATERIAL COLOR COLOR Hytrel Cream Cream Nitrile Black Red S Santoprene Tan Tan Santoprene Green N A Backu...

Страница 6: ...on surfaces and nicks or cuts in O rings S Take precautions to prevent cutting O rings upon installation S Lubricate O rings with Lubriplate FML 2 grease S Do not over tighten fasteners refer to torque specification block on view S Re torque fasteners following restart S SERVICE TOOLS To aid in the installation of 168 O rings onto the 167 pilot piston use tool 204130 T available from ARO PILOT VAL...

Страница 7: ...174 k 121 118 173 k 169 k 172 k 171 k 170 167 121 k 174 118 166 k 132 k 141 k 140 200 k 233 176 k PILOT VALVE PART GROUP MAJOR VALVE A replacement Major Valve Service Assembly is available separately which includes the following 637390 1 for models PD15P X 105 4 107 2 111 132 135 136 137 138 139 140 141 166 176 2 200 233 and 236 4 637390 2 for models PE15P X 76 105 4 107 2 111 132 135 136 137 138 ...

Страница 8: ...n col lapsing type capable of pulling a high vacuum S Check all joints on the inlet manifolds and suction connections These must be air tight S Inspectthepumpforsolidobjectslodgedinthediaphragmchamber or the seat area DIMENSIONAL DATA Dimensions shown are for reference only they are displayed in inches and millimeters mm Figure 4 Air Inlet 1 2 14 N P T Exhaust Port 3 4 14 N P T 1 1 2 A N S I DIN F...

Отзывы: