OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

 WARNING

 

EXCESSIVE AIR PRESSURE. Can cause personĆ

al injury, pump damage or property damage.

S

Do not exceed the maximum inlet air pressure as stated on the

pump model plate.

S

Be sure material hoses and other components are able to withĆ

stand fluid pressures developed by this pump. Check all

hoses for damage or wear. Be certain dispensing device is

clean and in proper working condition.

 WARNING

 

STATIC SPARK. Can cause explosion resulting

in severe injury or death. Ground pump and pumping system.

S

Sparks can ignite flammable material and vapors.

S

The pumping system and object being sprayed must be

grounded when it is pumping, flushing, recirculating or sprayĆ

ing flammable materials such as paints, solvents, lacquers,

etc. or used in a location where surrounding atmosphere is

conducive to spontaneous combustion. Ground the dispensĆ

ing valve or device, containers, hoses and any object to which

material is being pumped.

S

666056ĆXXX and 66605HĆXXX Groundable Acetal pumps: Use

the pump grounding screw provided. Connect a 12 ga. (min.)

wire (kit is included) to a good earth ground source.

S

Secure pump, connections and all contact points to avoid

vibration and generation of contact or static spark.

S

Consult local building codes and electrical codes for specific

grounding requirements.

S

After grounding, periodically verify continuity of electrical

path to ground. Test with an ohmmeter from each component

(e.g., hoses, pump, clamps, container, spray gun, etc.) to

ground to insure continuity. Ohmmeter should show 100

ohms or less.

S

Submerse the outlet hose end, dispensing valve or device in

the material being dispensed if possible. (Avoid free streamĆ

ing of material being dispensed.)

S

Use hoses incorporating a static wire.

S

Use proper ventilation.

S

Keep inflammables away from heat, open flames and sparks.

S

Keep containers closed when not in use.

 WARNING

 

Pump exhaust may contain contaminants. Can

cause severe injury. Pipe exhaust away from work area and

personnel.

S

In the event of a diaphragm rupture material can be forced out

of the air exhaust muffler.

S

Pipe the exhaust to a safe remote location when pumping hazĆ

ardous or inflammable materials.

S

Use a grounded 3/8" min. i.d. hose between the pump and the

muffler.

 WARNING

 

HAZARDOUS PRESSURE. Can result in serious

injury or property damage. Do not service or clean pump,

hoses or dispensing valve while the system is pressurized.

S

Disconnect air supply line and relieve pressure from the sysĆ

tem by opening dispensing valve or device and / or carefully

and slowly loosening and removing outlet hose or piping from

pump.

 WARNING

 

HAZARDOUS MATERIALS. Can cause serious

injury or property damage. Do not attempt to return a pump to

the factory or service center that contains hazardous material.

Safe handling practices must comply with local and national

laws and safety code requirements.

S

Obtain Material Safety Data Sheets on all materials from the

supplier for proper handling instructions.

CAUTION

 

Verify the chemical compatibility of the pump

wetted parts and the substance being pumped, flushed or reĆ

circulated. Chemical compatibility may change with temperaĆ

ture and concentration of the chemical(s) within the

substances being pumped, flushed or circulated. For specific

fluid compatibility, consult the chemical manufacturer.

CAUTION

 

Maximum temperatures are based on mechaniĆ

cal stress only. Certain chemicals will significantly reduce

maximum safe operating temperature. Consult the chemical

manufacturer for chemical compatibility and temperature limĆ

its. Refer to Pump Data on page 1 of this manual.

CAUTION

 

Be certain all operators of this equipment have

been trained for safe working practices, understand it's limitaĆ

tions, and wear safety goggles / equipment when required.

CAUTION

 

Do not use the pump for the structural support of

the piping system. Be certain the system components are

properly supported to prevent stress on the pump parts.

S

Suction and discharge connections should be flexible conĆ

nections (such as hose), not rigid piped, and should be comĆ

patible with the substance being pumped.

CAUTION

 

Prevent unnecessary damage to the pump. Do

not allow pump to operate when out of material for long periĆ

ods of time.

S

Disconnect air line from pump when system sits idle for long

periods of time.

CAUTION

 

Use only genuine ARO replacement parts to asĆ

sure compatible pressure rating and longest service life.

NOTICE

 

Install the pump in the vertical position. The

pump may not prime properly if the balls do not check by gravĆ

ity upon startĆup.

NOTICE

 

ReĆtorque all fasteners before operation. Creep

of housing and gasket materials may cause fasteners to loosĆ

en. ReĆtorque all fasteners to insure against fluid or air leakĆ

age.

NOTICE

 

Replacement warning labels are available upon

request: Static Spark" PN \ 93616Ć1, Diaphragm Rupture" PN

\ 93122.

 WARNING

CAUTION

NOTICE

= Hazards or unsafe practices which could

result in severe personal injury, death or

substantial property damage.

= Hazards or unsafe practices which could

result in minor personal injury, product or

property damage.

= Important installation, operation or

maintenance information.

Содержание 66605 series

Страница 1: ...charthowevercertaincomĆ binationsmaynotberecommended consultarepresentativeorthefactoĆ ry if you have questions concerning availability GENERAL DESCRIPTION The ARO Diaphragm Pump offers high volume delivery even at low air pressure and a broad range of material compatibility options available Refer to the model and option chart ARO pumps feature stall resistant design modular air motor fluid secti...

Страница 2: ...ile the system is pressurized S Disconnect air supply line and relieve pressure from the sysĆ tem by opening dispensing valve or device and or carefully and slowly loosening and removing outlet hose or piping from pump WARNING HAZARDOUS MATERIALS Can cause serious injury or property damage Do not attempt to return a pump to the factory or service center that contains hazardous material Safe handli...

Страница 3: ... Ć0DX come equipped with duckĆ bill type checks Standard duckbill pumps are shipped with the material inlet in the top and the material outlet on the bottom manifold To change the direction of flow disassemble the pump as instructed in the FLUID SECTION and reassemble as described below A pump that was factory built with balls and seats can be retroĆfitted with duckbill type check valves by purcha...

Страница 4: ...3760 E 93763 93761 93762 E ĆXX8 637140ĆX8 93112 U 93119 93117 93118 U ĆXXB 637140ĆXB 93465 SP 93763 93761 93762 E Ć0X1 637140ĆC1 D1 93113 N Y325Ć122 NOT REQ D Y325Ć120 B Ć0X2 637140ĆC2 D2 93465ĆG B Y325Ć122 NOT REQ D Y325Ć120 B Ć0X4 637140ĆC4 D4 93111 93465 T SP Y325Ć122 NOT REQ D 94749 T Ć0X8 637140ĆC8 D8 93112 U 93119 NOT REQ D 93118 U Ć0XB 637140ĆCB DB 93465 SP Y325Ć122 NOT REQ D Y325Ć120 B WET...

Страница 5: ...W COLOR CODE DIAPHRAGM BALL MATERIAL COLOR COLOR ACETAL N A ORANGE NITRILE RED RED S EPR BLUE BLUE S NEOPRENE GREEN GREEN S SANTOPRENE TAN TAN TFE WHITE WHITE URETHANE CLEAR RED VITON YELLOW YELLOW S STRIPE S DOT TORQUE REQUIREMENTS NOTE DO NOT OVERTIGHTEN FASTENERS 6 Diaphragm nut 95 Ć 105 in lbs 10 7 Ć 11 9 Nm 29 62 Fluid caps Manifold nuts 50 Ć 60 in lbs 5 6 Ć 6 8 Nm alternately and evenly then...

Страница 6: ... it may may helpful to proceed through step 5 and remove them once they are accessible from the inside of the fluid cap 3 Remove 35 bottom manifolds 36 swivel assembly 4 Remove 19 O rings 21 seats and 22 balls 5 Remove 15 fluid caps 6 Remove 6 diaphragm nut 8 7 Teflon Models only diaĆ phragm s and 5 diaphragm washer from 1 diaphragm connectĆ ing rod 7 Remove 1 connecting rod from air motor 8 Caref...

Страница 7: ...LY 1 Assemble 119 O rings 120 spacers and 142 washers on 118 pilot rod 2 Insert the stack into the 101 body Sleeve 103 may be used to assist pressing stack into body 3 Install 103 sleeve and 102 O rings into 101 body 4 Install 143 plates and 122 and 104 snap rings MAJOR VALVE DISASSEMBLY 1 Remove 129 exhaust cover and 130 gasket 2 Pull 135 valve block assembly from 101 body 3 Remove 134 bolts 133 ...

Страница 8: ...n the vertical posiĆ tion so that the balls will check by gravity S Check for pump cavitation suction pipe should be 1 2 min or larger if high viscosity fluids are being pumped Suction hose must be nonĆcollapsible type capable of pulling a high vacuum S Check all joints on intake manifolds and suction connections These must be airtight S Check for sticking or improperly seating check valves S If p...