Toronto
Italiano
05060106 01 27/08/2015
17
1. Introduction - Purpose of the manual/Field of application
This instruction manual is for the
Toronto
line of refrigeration units.
The information that follows is intended to provide instructions regarding:
Use of the unit - technical characteristics - installation and assembly - information for personnel
responsible for use - maintenance operations.
The manual should be considered part of the unit and should be kept for as long as the unit is in place.
The manufacturer considers itself released from any responsibility in the following cases:
Improper use of the unit - improper installation, not performed according to the instructions provided -
electrical power defects - serious deficiencies in carrying out scheduled maintenance - non-authorized
modifications or interventions - use of non-original spare parts - partial or total disregard for the instruc-
tions. This manual must be available for the operators and personnel assigned to maintenance, so as
to be consultable at any time. In the case that it is transferred to a third-party, the manual should be
provided to all new users or owners, providing appropriate and prompt communication of such to the
supplier. In the case of damage or loss, please contact your supplier.
All persons who use this unit must read this manual.
N.B.Electronic devices can be hazardous to health. The norms and laws in effect must be res-
pected during installation and use.
2. Presentation - Proper use (Fig. 1)
The
Toronto
line of refrigerator units, with double display tanks, is a line of "island" type display units,
appropriate for the conservation and self-service sales of
frozen foods, ice cream and meats
.The
unit is provided with sliding glass closures, which provide notable energy savings as well as better food
preservation.
3. Standards and certifications, conformity statement
All models of refrigerated cabinets described in this manual and belonging to the line:
Toronto
meet the essential requirements concerning safety, health at the workplace and protection
required by the following European Directives:
The performance of these refrigerated cabinets was determined through tests conducted in com-
pliance with standard:
EN ISO 23953:2012
in environmental conditions corresponding to climatic class 3 (25 °C , 60% U.R.)
see table:
Environmental climatic classes as per UNI EN ISO 23953
Directive
Harmonised standards applied:
Machinery Directive - 2006/42/CE
EN ISO 14121; EN ISO 12100-1; EN ISO 12100-2; EN 378-2;
EN 378-3; EN 378-4; EN 60079-10-1
2004/108/CE Electromagnetic Compatibility
EN 61000-3-2; EN 61000-3-12; EN 55014-1; EN 55014-2
2006/95/CE Low Voltage
EN 60335-1; EN 60335-2-89/A2
RoHs Directive 2011/65/CE;
(restricted use of certain hazardous
substances in electrical and electronic
equipment)
EN 50581
European Regulation
EC-1935/2004
(on materials intended for contact with the
goods)
EN 1672-2
Article 3 section 3 of Directive
CEE 97/23 (PED)
does not apply to these cabinets.
Climatic Class of the
testing chamber
Dry bulb temp. Relative Humidity
Dew point
Weight of water vapour in
dry air
°C
%
°C
g/kg
0
20
50
9,3
7,3
1
16
80
12,6
9,1
2
22
65
15,2
10,8
3
25
60
16,7
12,0
i
Содержание Toronto Series
Страница 4: ...Toronto 4 05060106 01 27 08 2015 10 1 2 3 4 a b ...
Страница 5: ...Toronto 05060106 01 27 08 2015 5 11 1 1 1 A B A CON LUCE WITH LIGHT ...
Страница 63: ...Toronto 4 00 18 04 2012 PORTUGUESA 10 1 2 3 4 a b ...
Страница 64: ...Toronto 00 18 04 2012 5 PORTUGUESA 11 1 1 1 A B A CON LUCE WITH LIGHT ...