Denver
English
22
05060085 01 13/07/2010
10) Lighting power (where foreseen)
11) Net display surface
12) Type of refrigerant fluid with which the plant operates
13) Mass of refrigerant gas with which each single plant is loaded
14) Environment climatic categories and reference temperature
15) Protection class against humidity
16) Job order number with which the cabinet has been manufactured
17) Order number with which the cabinet has been produced
18) Cabinet year of production
In case of technical assistance, in order to identify the cabinet communicate the following:
- the product name(Fig. 2 - 2); the serial number (Fig. 24); the job order number (Fig. 2 - 18);
5. Transport (Fig. 3)
The cabinets are supplied on a wooden support fixed to the base for movement with forklift trucks.
Always position the forks at the point specified on the wooden support to avoid the risk of
overturning
. Use a manual or electrical forklift truck that is suitable to moving the cabinet in question.
It must have a nominal capacity of at least 1,000 kg.
6. Receipt and first cleaning
On receiving the cabinet:
- Make sure that the packaging is integral and that there are no signs of evident damage;
- When unpacking do not damage the cabinet;
- Check all parts of the cabinet ensuring that its components are integral;
- If damaged, immediately call the supplier;
- Use neutral products for a first cleaning of the cabinet. Dry with a soft cloth and do not use abrasive
substances or metallic sponges.
When disposing of the packaging consider that it consists of:
Wood - Polyester - Polythene - PVC - Cardboard.
7. Installation and environment conditions (Fig. 3)
Do not position the cabinet:
- in environments where explosive gas substances are present;
- in open areas and therefore exposed to atmospheric agents;
- near to heat sources (direct solar light, heating plants, incandescent lamps etc.)
- near to air currents (doors, windows, air conditioning plants etc) that exceed the speed of
0.2m/sec
.
- Remove the wooden supports on the base (used for transport) and mount the adjustable feet (Rif. 2)
positioning them so that the cabinet is horizontally positioned and with the aid of a leveller (Rif. 1)
check its position. If the cabinet is moved repeat the levelling control.
- Before connecting the cabinet to the power line make sure that the data on the plate corresponds to
the characteristics of the electric plant to which it must be connected.
- For the cabinet to function correctly, the temperature and the environment relative humidity must
respect the parameters envisioned by the
EN-ISO 239531/2
standard that foresee Climatic Category
3 (
+25°C; U.R. 60%)
..
- Make sure that the ventilation openings of the condensing unit are not blocked.
N.B.All of these operations must be carried out by specialised technical staff.
8. Cabinets union
Channel union kit
Pos.
Name
Code
1
Union bracket for cabinets in channel
02211300
2
Rear upright support
02360519
3
Front upright Support bracket
02764465
4
Handrail alignment plug
02940652
5
M6 nut
04230400
6
M8 nut
04230600
7
TCEI M6x45 screw
04710028
8
TCEI M8x120 screw
04711065
9
M4x10 EI dowel
04710026
10
D 8x17 washer
04480104
11
AF TC 3.9x13 screw
04705015
12
TCEI M6x20 screw
04711003