background image

30

Armstrong International - Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093

USA Phone: 269-279-3602 Fax: 269-279-3130 - armstronginternational.com

In the Frequency panel click on + 

or – to adjust how often you want 

the duty flush to take place. 

In the Temperature panel scroll up 

or down or click + or – to adjust the 

temperature of the duty flush.

In the Flow Rate panel scroll up or 

down or click + or – to adjust the 

flow rate of the duty flush. 

9

11

10

Содержание Rada

Страница 1: ...1 Armstrong International Hot Water Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Rada Digital Faucet App Programming Guide...

Страница 2: ...ius 13 Change the default pin 14 Set operation mode On Off 16 Allow the use of full cold 18 Select the temperature adjustment and default temperature 20 Select normal operating flow 22 Set operational...

Страница 3: ...I 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com View data logs 51 Export data logs 54 Example of data logs 55 Accessing and exporting data logs 51 Run a temperature check 56...

Страница 4: ...rogramming the Rada Digital Faucet Search Rada AP1 The App is only compatible with an Apple iPad It is currently not compatible with Apple iPhones or Android devices The IOM is available from Armstron...

Страница 5: ...rnational com Connecting your iPad to the Rada Digital Faucet Open the Rada AP1 App on your iPad Ensure Bluetooth is enabled on your iPad Put the Faucet into service mode by placing the Rada Magnetic...

Страница 6: ...ginternational com Click on Bluetooth The App will search for the Faucet Ensure you are near the Faucet you re programming and the spanner wrench is red You ll see the Faucet appear in the Valve Searc...

Страница 7: ...3 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com The faucet is connected when the indicator bars are lit Once connected click the back button to return to the home screen you can d...

Страница 8: ...n Valve Setup Set the date and time Create a unique Faucet name Setting the Region Language and Chosing Fahrenheit Celcius Changing the Default Pin Note To perform thermal disinfection and duty flush...

Страница 9: ...e Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com In the Valve and Date panel select either the Time and or Date field Scroll to set current date and time When compl...

Страница 10: ...ivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com The Faucet will let you know it is making the changes Note any other changes made in other tiles will be applied when...

Страница 11: ...69 279 3130 armstronginternational com Click on Valve Setup Creat a unique name 1 2 Click Edit in Installation Setup panel In the Valve Identity panel click on ID Setting a unique faucet name will ens...

Страница 12: ...12 Armstrong International Hot Water Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Click for forward arrow Click Apply to Valve 4 5...

Страница 13: ...30 armstronginternational com Set the Region language and choose Fahrenheit Celsius Click on the General Settings Panel The default language setting will be based on the region your iPad is set to Cho...

Страница 14: ...enables you to alter factory settings including maximum blend temperature and run time You can also download thermal disinfection and duty flush data You can set a unique pin for every Faucet Once yo...

Страница 15: ...International Hot Water Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com In the Pin panel enter and confirm your new four digit pin Cli...

Страница 16: ...armstronginternational com Set the outlet for your application Here you can Selecting operation mode On Off Blocking TImed Allowing use of full cold Selecting default temperature and temperature adjus...

Страница 17: ...erate in On Off mode is the default setting This mode enables the Faucet to operate as a non touch faucet Water will run when your hands are in range and water will stop when you remove your hands Tim...

Страница 18: ...hree Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Allow the use of full cold Click on Valve Setup 1 2 Click Edit in Outlet Setup panel In the Full Code Mode panel...

Страница 19: ...19 Armstrong International Hot Water Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Click Apply 5 Click for forward arrow 4...

Страница 20: ...tronginternational com Click on General Settings Select the temperature adjustment and default temperature 2 1 In the Minimum Temperature panel scroll up or down or click or to adjust to the minimum b...

Страница 21: ...21 Armstrong International Hot Water Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Click the forward arrow Click Apply 4 5...

Страница 22: ...e 269 279 3602 Fax 269 279 3130 armstronginternational com Click on Valve Setup Select normal operating flow The default flow rate of 1gpm at 60 psi is suitable for most applications 1 Click Edit in O...

Страница 23: ...093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com In the Default Flow Rate panel scroll up or down or click or to adjust the flow rate Note pause between adjustments to enable the...

Страница 24: ...269 279 3130 armstronginternational com Click on Valve Setup Set operational timings These settings are important to ensure a great user experience If Timing mode is unavailable for outlet mode selec...

Страница 25: ...run In the Run Time panel scroll up or down or click or to adjust Note This is only used when the Faucet is programmed to On Off mode This is the time the Faucet will run when the user is longer detec...

Страница 26: ...Phone 269 279 3602 Fax 269 279 3130 armstronginternational com In the Blocking Time panel scroll up or down or click or to adjust Note This is only used when the Faucet is programmed to Blocking mode...

Страница 27: ...nternational com Set automated duty flush parameters and manual activation Here you can Set automated duty flush and manual activation Set automated cold flush and manual activation Set thermal disinf...

Страница 28: ...1 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Click on Duty Flush Click Edit in Setup panel Note either 2 or 3 opens the configuration scree...

Страница 29: ...ck between flushes to determine if the Faucet was used for a time equal to or greater than the flushing duration If this condition it met it will skip the duty flush and log it as skipped You can chan...

Страница 30: ...armstronginternational com In the Frequency panel click on or to adjust how often you want the duty flush to take place In the Temperature panel scroll up or down or click or to adjust the temperatur...

Страница 31: ...ach the programmed duty flush temperature Note the total duty flush includes the time it takes to get to temperature and the duty flush If the Faucet fails to see the set temperature the Faucet will l...

Страница 32: ...ivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Manually trigger a duty flush at any time Click on Duty Flush In the Flush Feedback panel click Trigger and a ten seco...

Страница 33: ...1 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Once duty flush is complete you can view the result by clicking on the Latest Results panel 19...

Страница 34: ...oup 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Set automated cold flush and manual activation Click on Valve Setup Click Edit in Cold F...

Страница 35: ...rong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Click Edit in Setup panel Note either 2 or 3 opens the configuration screen Select Standard in the Ty...

Страница 36: ...rnational com In the Activation panel scroll up or down or click or to adjust the time of day you want the cold flush to occur In the Duration panel scroll up or down or click or to adjust the duratio...

Страница 37: ...ld Flush Max panel scroll up or down or click or to adjust the maximum temperature for the cold flush 10 11 In the Cold Flush Min Time Out panel scroll up or down or click or to adjust the length of t...

Страница 38: ...69 279 3130 armstronginternational com Click the forward arrow In the Flow Test panel click Start and water will start to flow In the Flow Rate panel scroll up or down or click or to adjust the flow r...

Страница 39: ...ng International Hot Water Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com In the Flow Test panel click Stop to stop the water Click A...

Страница 40: ...vers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Manually trigger a cold flush at any time Click on Valve Setup In the Flush Feedback panel click Trigger and a ten seco...

Страница 41: ...1 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Once cold flush is complete you can view the result by clicking on the Latest Results panel In...

Страница 42: ...mstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Set thermal disinfection and manual activation Click on Valve Setup Click Edit in Thermal Disinfec...

Страница 43: ...stronginternational com Click Edit in Setup panel Note either 2 or 3 opens the configuration screen Select Standard in the Type panel Note Standard Cold can be used if can send hot water through your...

Страница 44: ...down or click or to adjust the flow rate of the thermal disinfection Note the default is set to 10 to maximise water and energy savings In the Warm Up Time scroll up or down or click or to adjust the...

Страница 45: ...Phone 269 279 3602 Fax 269 279 3130 armstronginternational com In the Timeout panel scroll up or down or click or to adjust the duration of the thermal disinfection Note the time set should be equal...

Страница 46: ...093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Click on Thermal Disinfection In the Flush Feedback panel click Arm In the Flush Feedback panel click Trigger and a ten second co...

Страница 47: ...MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com To cancel the thermal disinfection click Abort Once thermal disinfection is complete you can view the result by clicking on...

Страница 48: ...Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Saving and applying a preset Save a preset Once you ve completed the setup for an application it is recommended you save the setup as a p...

Страница 49: ...21 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Name the preset Note This is a 16 digit field Click OK The preset will now show on your list...

Страница 50: ...er Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Applying a preset In the Select Preset panel click the preset name 16 digit field C...

Страница 51: ...USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Accessing and exporting data logs View data logs Ensure you are connected to the Faucet you to view the data log for Click Save in Vi...

Страница 52: ...Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Select start Date and Time in Form panel Select end Date and Time in Form panel Select the data...

Страница 53: ...vd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Select data your wish to view i e All Data or Errors Click View in View Export panel You can select data log...

Страница 54: ...ional Hot Water Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Exporting data logs Click Export in View Export panel Select Mail To e...

Страница 55: ...national Hot Water Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Example of data logs Usage Log Duty Flush Log Cold Flush Log Therma...

Страница 56: ...3130 armstronginternational com Run a temperature check Click Data Logging Click Arm in Flush Feedback panel Click Trigger and a ten second countdown will start Note The Faucet measures the available...

Страница 57: ...Fax 269 279 3130 armstronginternational com Valve health checks Select Valve Health Check panel Health check panels explained Once temperature check is complete you can view the result by clicking on...

Страница 58: ...ronginternational com In the Current Status panel the Valve Health is displayed The Valve Status will always be Cleaning Mode The Current Setpoint panels displays the default temperature selected The...

Страница 59: ...nal com The 7 Day Usage Data panel displays the last seven days in number of activations and total time the Faucet has been used each day The Last Flush Results panel displays a The latest duty flush...

Страница 60: ...3602 Fax 269 279 3130 armstronginternational com Click Clear Valve Error panel to clear an error The Time and Date panel displays the current time and date The Last Service Date Time panel displays t...

Страница 61: ...national Hot Water Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com Click on Valve Health Check Clear an error Click Clear in Clear Val...

Страница 62: ...62 Armstrong International Hot Water Group 221 Armstrong Blvd Three Rivers MI 49093 USA Phone 269 279 3602 Fax 269 279 3130 armstronginternational com...

Отзывы: