Armstrong Rada 320 Скачать руководство пользователя страница 12

12

Limited Warranty and Remedy

Armstrong Hot Water Group, Inc. (“Armstrong”) warrants to the original user of those products supplied by it and 

used in the service and in the manner for which they are intended, that such products shall be free from defects in 

material and workmanship for a period of one (1) year from the date of installation, but not longer than 15 months 

from the date of shipment from the factory [unless a Special Warranty Period applies, as listed below]. This 

warranty does not extend to any product that has been subject to misuse, neglect, or alteration after shipment 

from the Armstrong factory. Except as may be expressly provided in a written agreement between Armstrong and 

the user, which is signed by both parties, Armstrong 

DOES NOT MAKE ANY OTHER REPRESENTATIONS OR 

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY 

OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE

The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim 

relating to the products or to defects or any condition or use of the products supplied by Armstrong, however 

caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis 

or theory, is limited to Armstrong’s repair or replacement of the part or product, excluding any labor or any other 

cost to remove or install said part or product, or, at Armstrong’s option, to repayment of the purchase price. As 

a condition of enforcing any rights or remedies relating to Armstrong products, notice of any warranty or other 

claim relating to the products must be given in writing to Armstrong: (i) within 30 days of last day of the applicable 

warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise 

to the claim, whichever is earlier. 

IN NO EVENT SHALL ARMSTRONG BE LIABLE FOR SPECIAL, DIRECT, 

INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF 

USE OR PROFITS OR INTERRUPTION OF BUSINESS.

 The Limited Warranty and Remedy terms herein apply 

notwithstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or 

third party and all such contrary terms shall be deemed rejected by Armstrong.

Armstrong International
221 Armstrong Blvd., Three Rivers, Michigan 49093 - USA
Ph: (269) 279-3602   Toll Free: (888) HOT-HOSE (468-4673)   Fax: (269) 279-3130

           

ALIB-320-C

Rada 320

Printed in U.S.A. - 5/12

© 2012 Armstrong International, Inc.

Designs, materials, weights and performance ratings are approximate and subject to change without notice.

Visit 

armstrong

international.com for up-to-date information.

Special Warranty Periods are as follows:

Flo-Direct Gas Fired Water Heater

The stainless steel structure and stainless steel internals (flame, tube, pall rings, supports, etc.) shall 

have a ten (10) year non-prorated guarantee against burn out or any structural failure caused by 

materials and workmanship. Provided only clean potable water is heated. The other components on the 

Flo-Direct, such as valves, combustion equipment, electrical controls, and the burner shall have a two 

(2) year non-prorated guarantee against failure caused by materials and workmanship.

Flo-Rite-Temp Instantaneous Water Heater

The tube bundle shall have a 10-year guarantee against failure caused by materials or workmanship 

provided by Armstrong but not against gasket failure or damage caused by corrosion, water hammer or 

lack of proper cleaning.

Flo-Rite-Temp Packaged Instantaneous Water Heater

Two (2) years from the date of installation, but not longer than 27 months from the date of shipment. 

See above for tube bundle guarantee.

Flo-Eco High Efficiency Gas Water Heater

The heat exchanger and supplied integral components such as the burner, the electrical controls and 

valving shall have a two (2) year warranty from the date of installation but no longer than 27 months 

from the date of shipment. The tank and replaceable tank liner shall have a 5 year warranty from the 

date of shipment.

The Brain – Model DRV80

 and derivative assemblies shall have a 5-year all component parts warranty.

Содержание Rada 320

Страница 1: ... Valve is configured for use in a dead leg piping configuration as indicated in the drawing on Page 5 This Rada 320 Valve has not been configured for use in a central pumped re circulation system This Rada 320 Valve has not been designed to deliver tepid water to Emergency Fixtures For further information please call our technical department Toll Free at 1 888 HOT HOSE Model No Rada 320 Rada 320D ...

Страница 2: ...l Specifications Dual thermostatic elements provide redundancy in the event of individual thermostat failure Typical outlet temperature control 2 F Adjustable maximum temperature limit stop Adjustable single temperature lockout Thermal shutdown mode upon inlet supply failure Technical Specifications 1 NPT inlets and 1 NPT outlet Chrome plated DZR brass polymer construction Operating pressures Maxi...

Страница 3: ...thermostatic elements provide redundancy in the event of individual thermostat failure Typical outlet temperature control 2 F Adjustable maximum temperature limit stop Adjustable single temperature lockout Thermal shutdown mode upon inlet supply failure Technical Specifications 3 4 NPT inlets and 3 4 NPT outlet Chrome plated DZR brass polymer construction with self finish brass and bronze componen...

Страница 4: ...roduct failure and its associated consequences if not eliminated are reduced to the minimum achievable Rada 320 Operating Specifications Rada 320 can accept temporary excursions above 185 F 85 C and maintain control without sustaining internal damage ASSE 1017 certification requires exposure to 200 F 93 C for a period of 30 minutes Prolonged operation of the Mixing Valve at such elevated temperatu...

Страница 5: ...e outlet as close to the mixing valve as feasible to facilitate check valve and inlet strainer screen service and replacement 4 Be sure to thoroughly flush the pipework before fitting the Rada 320 5 Be sure to make up all sweat or soldered fittings ahead of time Do not expose Rada 320 or any of its fittings to extreme temperatures such as an acetylene or propane torch 6 Rada 320 is serviced from t...

Страница 6: ...ck that an adequate supply of hot water is available at the hot inlet of the mixing valve For optimum performance the minimum temperature of the hot water must be at least 21 F 12 C above the desired blend however during resetting this should be close to the typical storage maximum to reduce the possibility of any blend shift due to fluctuating supply temperatures Temperatures should always be rec...

Страница 7: ...ons such as high mineral content water dictate It is highly recommended that as a function of the annual inspection that the two racetrack shaped o seals within the valve are replaced D33387 seal pack Rada 320 Thermostatic Mixing Valve is of non serviceable single cartridge construction The cartridge can be removed from the valve for inspection or replacement by first removing the chromed brass te...

Страница 8: ...seals are pre lubricated If further lubrication is required use only silicone based lubricants on this product Do not use petroleum based lubricants Step 1 Step 2 Step 3 Figure 8 2 Body Cartridge Guides Temperature Spindle Temperature Indicating Ring Temperature Knob Screw 3 mm Hexagon Wrench Hub Screw Cartridge Cut out To Aid Removal Cartridge Assembly H and C marked on cartridge Make sure that t...

Страница 9: ...3386 Inlet Outlet Adapter 3 4 Female D33387 Seal Pack Includes A Components D33388 Screw Pack Includes B Components D33389 Backplate Kit Includes C Components D33390 Knob Pack with Screw D33391 Blanking Cap D33392 Outlet Adapter 1 Male D33393 Inlet Adapter with Check Valve 1 Male 3 4 NPT Female D33386 1 NPT Male D33392 1 NPT Male with Integral Strainer and Check Valve D33393 ...

Страница 10: ...lity to correct Check Rectify e Hot water supply temperature fluctuating beyond valves capability to correct Check by carefully sensing inlet hot supply pipe work rectify f Partially occluded screens filters or partially blocked inlet fittings Check Rectify 4 Hot water in cold supply and vice versa a Indicates non functioning check valve s Diagnose by turning off mixed water outlet flow and check ...

Страница 11: ...11 Notes ...

Страница 12: ...AL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS The Limited Warranty and Remedy terms herein apply notwithstanding any contrary terms in any purchase order or form submitted or issued by any user purchaser or third party and all such contrary terms shall be deemed rejected by Armstrong Armstrong International 221 Armstrong Blvd Three Rivers Michigan 49093...