The control box should be located in a dry location and not 
exposed to dirt, dust or damp. The unit should be accessible when 
required, but not within easy reach of unauthorised persons.

It will be necessary to make adjustments and service the control 
box after installation, and in the future. Secure access areas and 
duct spaces are recommended. 

The control box is not designed for direct surface mounting into 
washroom areas. Never open the cover with the supply live.

The routes that cables will take when connecting external 
equipment to the control box should also be planned at this stage.

The shower control system is typically used with a high security 
shower head. 

Important: Thermostatic mixing valve

It is recommended that hot water is supplied through an approved 
TMV3 thermostatic mixing valve to prevent scalding (sold 
seperately).

Step 3 : 

Typical installation

Step 2 : 

Kit Contents

Step 1 : 

Safety First

These instructions relate to the use of the Shower Control System 
only, any external or ‘add-on’ parts will be supplied with separate 
instructions. 

It is recommended that the electrical part of the installation be 
carried out by a qualified electrician in accordance with the latest 
electrical regulations. It is also recommended that any plumbing 
is carried out by a qualified plumber.

*Not to scale

IMPORTANT :

 Please read these instructions carefully  

and follow each stage in order!

IMPORTANT : 

It is recommended that hot water is supplied 

through an approved TMV3 thermostatic mixing valve (sold 
seperately), in order to prevent scalding.  

Step 5 : 

Fixing & wiring

 

Step 4 : 

Board layout

 

Input connection - Sensor 1
Output connection - Valve 1
Input connection - Sensor 2
Output connection - Valve 2
Cable entry - Sensor 1
Cable entry - Valve 1
Cable entry - Sensor 2
Cable entry - Valve 2
Mains supply
Time setting switches
Option switches
LED 1 - For engineers / testing only
LED 2 - For engineers / testing only
LED 3 - For engineers / testing only
Fuse (replace with exact same type)

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

9

15

12

10 11

14

13

4

3

8

7

6

5

2

1

DO NOT extend cables
DO NOT leave badly fitted cables
DO NOT interfere with the mains flex
DO check all cables and connections
DO ask for advice if / when necessary  

The box should be securely fixed in a suitable location in a 
horizontal orientation, so that the front label is read correctly. 

Remove lid to expose four fixing locations around the edge of the 
enclosure (see Fig. 3). These areas allow the fastening of the unit 
without removing the printed circuit board. 

Drill through these marked areas away from the wall to avoid dust 
entering the control box, then hold control box in position against 
the wall and mark holes with a pencil. Remove box, drill and plug 
marked areas and fix the control unit with suitable fixings.

Connect the mains supply lead to a 230V ac supply via a fused 
spur, the fuse rating should be 3 Amps. The mains supply should 
NOT be initiated until all external equipment has been installed 
and wired.

Always read instructions supplied with external components and 
ensure that only the supplied equipment is connected to the 
control box.

Cables should enter the enclosure through the cable glands. Keep 
all connections tidy and do not allow cable to finish or hang in the 
transformer area. . 
It is recommended that each cable is fed through the relative 
cable gland into the enclosure; the cable can then be pulled out 
towards the fitter to allow the connector plugs to be fitted.

The connector plugs can be disconnected from the mating 
sockets when wiring external equipment, double check positions 
with the plug orientations as they only fit one way!

When each plug has been wired the cables can be pulled back 
through the cable glands, and the plug re-connected to the 
corresponding socket. Cables should not be left to torte or slack.

When all connections are made and checked, replace the lid and 
secure.

Fixing locations

Fuse

Connector plug

Fixing screw

Sensor (x1 or x2)

Solenoid valve (x1 or x2)

Control box

0870 122 8822

 

Sensor

Control box

Shower head

Mixed water

TMV mixing valve

Solenoid valve

Hot

Cold

Your kit will include the following parts*: