Switch C, Selects lockout on or off. In the ON position each valve 
can be opened 4 times in a 15-minute block. The after each 15 
minute block, both valve counts are reset.

Purging Notes:

When a valve is operated, the purging timer for that valve is reset. 
The timer is reset from the time that the timer starts, so the purge 
frequency is as set minus the valve open time.

The frequency ( time between purges ):- 24Hrs 

Step 7 :

 Time settings and basic operation

Step 6 :

 Option setup

Sentry21 

Shower Control System 

Installation & Operating Instructions

03

03

14

03

03

14

Armitage Shanks

 | 

Armitage

 | 

Near Rugeley

 | 

Staffordshire

WS15 4BT 

England 

|

 +44 (0)870 122 8822

Customer Care He44 (0)844 5436170

 | 

Fax +44 (0)844 5436171

 | 

[email protected]

As seen in the drawing below, the control box is supplied with a 
4-way DIP switch and 3 in-line ON/OFF switches.

The first 3 DIP switches sets the valve open time, once activated 
by the corresponding  sensor. The 4th DIP switch selects if the 
valve can be closed before the run time is reached, by operating 
the sensor again.
The numbers on the switches i.e. 1,2,3 & 4 simply identify the 
switch number; actual time settings available are shown below.

There are also 3 in-line switches fitted to the right side of the DIP 
switches.

Settings:

Switch A, when set to ON selects ‘tap mode’, when set
to OFF selects ‘shower mode’. The only difference
between the 2 modes is the available valve open time is longer
for the shower mode.  

Switch B, Selects purging ON or OFF. When set to ON  the valve 
opens for the set open time automatically if it has not been 
operated during the purge time. Each valve has independent 
purge operation, but the settings relate to both. The purge 
frequency is every 24 hours.

AB

C

ON

ON

ON

Time settings: ( First 3 DIP switches ).
Both the Tap mode and Shower mode have default time settings, 
i.e. if all of the first 3 DIP switches were set to off default settings 
would apply. The DIP switches add time to these default settings.

The default time for the shower mode is 30 seconds. The default 
time for the Tap mode is 6 seconds. This time can then be 
increased by using any combination of the DIP switches as shown, 
time in brackets is for the Tap mode.

Switch 1 = Adds 30 Seconds ( Adds 2 Seconds )
Switch 2 = Adds 60 Seconds ( Adds 4 Seconds )
Switch 3 = Adds 60 Seconds ( Adds 8 Seconds )

Any combination of switches can be set to on i.e. in the up 
position, the setting adds up so that the time range available is:-

Shower settings; 30 seconds ( default ) - 180 seconds or 3 
minutes.
Tap settings; 6 seconds ( default ) – 20 seconds.

When all connections and settings are made and checked, replace 
lid and secure. After installation and setting of external equipment, 

ON

12

34

e.g. sensors, valves etc. the supply should be connected.

Wave-on / Wave-off settings

Switch 4 ON enables Wave-on / Wave-off operation which allows 
the valves to be waved off before the set time has finished. If not 
waved off manually the valves will close automatically at the set 
time as usual.

Power up

When all connections and settings are made and checked, replace 
the lid and secure.

After installation of external equipment, such as sensors and 
valves etc, the supply should be connected.

Operation

When the control box is powered any connected valves will be 
opened for 2 seconds, the valves will close and after a short 
period normal operation will begin.

The time period between the valves opening and normal operation 
will depend on the set time, therefore this could be up to 20 
seconds.

When a sensor is operated the corresponding valve will open for 
the set time, if DIP switch 4 has been set to on, the valve can be 
closed before the set time by operating the sensor a second time.

Each off the two channels operates independently, but both use 
the same settings.

Page

 4

IMPORTANT :

 Changes to settings can only take place when 

power has been disconnected for at least 5 seconds.

IMPORTANT :

 Changes to settings can only take place when 

power has been disconnected for at least 5 seconds.

S331001
S331101
S331201
S331301

0870 122 8822

 