![Armitage Shanks Sensorflow 21 A4851AA Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/armitage-shanks/sensorflow-21-a4851aa/sensorflow-21-a4851aa_installation-instructions-manual_2973809007.webp)
Inline
solenoid
valve
Inline service
valve with filter
Inlet adaptor
15 to 8mm
compression
2x Couplers
G1/2” female
thread to
15mm
compression
Spout inlet
pipe Ø8mm
Short copper
pipe Ø15mm
Short copper
pipe Ø15mm
Copper supply
pipe Ø15mm
Filter
cap
Isolating
screw
FLOW
DIRN
FLOW
DIRN
16, 22 & 24
7
5.2
Plumbing Overview
Once the spout has been secured to the ba-
sin, consideration should be given to install-
ing & positioning of the inline valves.
A typical plumbing installation example is
shown here. The water is being supplied from
below, but can be from any direction.
Short lengths of Ø15mm copper pipe
(not supplied) have been used between the
components. Copper pipe lengths should be
cut to suit the suit the installation.
Note the Ø8mm inlet pipe (fitted to spout) can
be trimmed if necessary.
Observe arrow markings on the
valves as shown here. Ensure water
flows in the direction indicated.
4. To fit inlet adaptor:
Slip the small com-
pression nut & olive onto the Ø8mm inlet
pipe. Push the adaptor onto the inlet pipe up
to the shoulder. Slide the olive up to the adap-
tor & tighten the compression nut
(16mm A/F) with an adjustable spanner. Hold
the adaptor steady with 22mm A/F spanner.
INSTALLATION GUIDE continued…