11
10
6
7
8
9
24
24 & 25
Connection of this product to mains
power supply should be undertaken by
a competent person and should conform to
IEE Wiring Regulations
Orientation & position of solenoids, and PSU
(
P
ower
S
upply
U
nit) case can differ from installa
-
tion to installation.
With the product securely mounted to the basin &
plumbed-in, electrical work can commence.
12.
Locate the end of the red & black cable which
emerges from the spout tail (attached to the rear of
the sensor). This cable length is nominal 800mm.
Connect the cable to the solenoid valve terminals
as
shown. Observe the + and – symbols marked on
the
solenoid valves, connect the red cable to + &
black to -.
Refer to the diagram on the next page for PSU
connection options.
12
red
black
Power:
6W
Approval EU:
EN 60950, EN 60335
Approval UL:
UL 1310
Input voltage:
100V - 240V~ 50 - 60Hz
Protection class:
II
DIN EN 60730-1: Type 1
Each type of PSU is
identified by this
coloured dot system:
RED
DOT
BLUE
DOT
GREEN
DOT
MAINS
LINK
BATTERY
9
5.3
Electrical connection
Electrical information
& approvals:
IEE (BS 7671) In the interest of electrical safety, ensure all wiring conforms to the latest standard UK
IEE Wiring Regulations.
Always ensure mains power supply is switched off before
commencing any electrical connection work.
ELECTRICAL SAFETY
NOTE: Children must not be allowed to
clean or maintain this product