Arman PRE4000K Скачать руководство пользователя страница 27

Page 26

FIRMAN GENERATOR 3 YEAR LIMITED WARRANTY

Proof of purchase must be presented when requesting warranty service.
This product is manufactured by SUMEC MACHINARY & ELECTRIC Co, Ltd. 

WHAT IS COVERED UNDER THE 3 YEAR LIMITED WARRANTY

This FIRMAN® generator is warranted to the original purchaser only to be free from 
defects in material and workmanship subject to certain exceptions and limitations stated 
below, for a period of three (3) years after date of purchase.

WHAT IS NOT COVERED

This warranty does not apply to damage from misuse, alterations, abuse, normal wear and 
tear, lack of maintenance, accidents, or repairs made or attempted by anyone other than 
an authorized service center for FIRMAN® generators.
This warranty does not cover repair if:

Normal use has exhausted the useful life of the generator and wear and tear items 
(including batteries, fixed and removable control panels including corresponding 
cords and plugs, digital displays, tires, outlet plugs and circuit breakers, switches, 
and extension cords if applicable)
The customer fails to install, maintain, and operate the product in accordance with 
the instructions and recommendations of the company set forth in the generator 
operator’s manual 
The product is used as rental equipment.
Damage occurs due to freezing, water exposure, rust, corrosion, thermal expansion, 
fire, dropping, or improper use.


This warranty does not cover freight or labor charges associated with the inspection and 
testing of generators which are found not to be a valid warranty claim.

HOW TO OBTAIN SERVICE

To obtain service for this 

FIRMAN

 generator you must return it, freight prepaid, or take 

it  in  to  a  manufacturer-authorized  service  center  for 

FIRMAN

  generators.  You  may 

obtain  the  location  of  the  authorized  service  center  nearest  you  by  calling  (toll  free)
  1-844-Firman1  (1-844-347-6261)    or  by  logging  on  to  the 

FIRMAN

  website  at 

www.firmangenerators.com.  When  requesting  warranty  service,  you  must  present  the 
original  dated  sales  receipt.  The  authorized  service  center  will  repair  any  faulty 
workmanship, and either repair or replace any part covered under the warranty, at our 
option, at no charge to you.

ADDITIONAL LIMITATIONS

To the extent permitted by applicable law, all implied warranties, including warranties of 
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE, are disclaimed. Any implied 
warranties, including warranties of merchantability or fitness for a particular purpose, 
that cannot be disclaimed under state law are limited to three years from the date of 
purchase. SUMEC North America, are not responsible for direct, indirect, 
incidental, or consequential damages. Some states do not allow limitations on how long 
an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or 
consequential damages, so the above limitations may not apply to you. This warranty 
gives you specific legal rights, and you may also have other rights which vary from state 
to state.
This warranty applies to product sold in the U.S.A., Canada, and Mexico only.

Содержание PRE4000K

Страница 1: ...carefully before operating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining...

Страница 2: ...e not followed Indicates a possibility of personal injury or equipment damage if instructions are not followed Gives helpful information If a problem should arise or if you have any questions about th...

Страница 3: ...d to proper oil level See Add Engine Oil Fuel tank filled at or below baffle See Add Fuel Inspect fuel lines tank cap and fittings each time before using generator DO NOT use if fuel leak or damage is...

Страница 4: ...ECIFICATIONS 08 3 COMPONENTS 09 4 PRE OPERATION CHECKS 10 5 OPERATING PROCEDURES 14 6 SERVICING THE GENERATOR 18 7 HOW TO MAINTENANCE 29 8 PREPARATION FOR STORAGE 22 9 TROUBLE SHOOTING 23 10 WARRANTY...

Страница 5: ...de alarms or plug in carbon monoxide alarms with battery back up according to the manufacturer s instructions Smoke alarms cannot detect carbon monoxide gas DO NOT run this product inside homes garage...

Страница 6: ...e Keep fuel away from sparks open flames pilot lights heat and other ignition sources Check fuel lines tank cap and fittings frequently for cracks or leaks Replace if necessary DO NOT light a cigarett...

Страница 7: ...water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaust heat gases could ignite combustibles structures or dama...

Страница 8: ...speeds impose a heavy load DO NOT tamper with governor spring links or other parts to increase engine speed Generator supplies correct rated frequency and voltage when running at governed speed DO NOT...

Страница 9: ...wheel Magneto Unleaded Automotive Gasoline Recoil 4 Gallon 20oz Lubricating Oil Capacity Counter Clockwise Facing P T O Float Brush Polyurethane Type Carburetor Type Air Cleaner Alternator Type P T O...

Страница 10: ...ER 9 RECOIL STARTER 10 OIL DRAIN PLUG 11 OIL FILLER CAP 12 GROUND TERMINAL 13 AIR CLEANER 14 SUPPORTING LEGS 15 MUFFLER 16 FUEL TANK 17 HANDLE FRAME 18 WHEELS A Digital display B AC voltage indicator...

Страница 11: ...following tools to install the wheels 21mm wrench or adjustable wrench not included Socket wrench with a 13mm socket not included Pliers not included 1 Before adding fuel and oil tip the generator on...

Страница 12: ...il level is below the lower level line refill with suitable oil see table below to upper level line Do not screw in the oil filler cap when checking oil level Multigrade Ambient 20 10 0 10 20 30 40 4...

Страница 13: ...ore refueling with fuel Be careful not to admit dust dirt water or other foreign objects into fuel Wipe off spilt fuel thoroughly before starting engine Keep open flames away Be sure to use the fuel f...

Страница 14: ...r tilt Two wheels help you to move the generator very relaxed CHECKING GFCI To reduce chance of electrical shock 1 Do not attempt to operate equipment if ground fault circuit interrupter GFCI RESET bu...

Страница 15: ...l cock ON 3 Turn engine switch to ON position and pull rope or push start button for electric start 4 Turn choke lever OFF after engine is warm If engine does not start repeat operation until engine s...

Страница 16: ...ughly tested and adjusted in the factory If the generator does not produce the specified voltage consult your nearest FIRMAN Generator dealer Be sure that the total wattage of all appliances does not...

Страница 17: ...increased fuel consumption and spark plug fouling To alleviate high altitude issues other than the natural power loss FIRMAN can provide a high altitude carburetor main jet The alternative main jet an...

Страница 18: ...power switch of the electric equipment or unplug the cord from receptacle of the generator b Allow the engine about 3 minutes to cool down at no load before stopping c Set the engine switch to OFF po...

Страница 19: ...Do not pour it down into sewage drains onto garden soil or into open streams Your local zoning environmental regulations will give you more detailed instructions on proper disposal Items marked with...

Страница 20: ...lure Replace all bent or damaged components 1 Remove screw C and air cleaner cover A 2 Remove foam element B from air cleaner base D 3 Wash foam element B in warm water with detergent Rinse and allow...

Страница 21: ...trode gap to 0 7 to 0 8 mm 0 028 to 0 031 SPARK PLUG NGK BPR6HS equivalent Dirt and water in the fuel are removed by the fuel strainer a Remove the strainer cup and throw away water and dirt b Clean t...

Страница 22: ...ng in death or serious injury Contact with muffler area could cause burns resulting in serious injury Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead Contact the o...

Страница 23: ...rting difficult Loosen the drain screw on the bottom of the carburetor float chamber and drain the fuel completely Change engine oil Check for loose bolts and screws tighten them if necessary Clean ge...

Страница 24: ...lever is in OFF 0 position 3 Low oil level 4 Dirty air cleaner 5 Out of fuel 6 Stale fuel 7 Spark plug wire not connected to spark plug 8 Bad spark plug 9 Water in fuel 10 Flooded 11 Excessively rich...

Страница 25: ...TIAL DAMAGES OF ANY KIND Some states or countries do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limi...

Страница 26: ...n the owner s manual supplied is warranted for the warranty period stated above Any such part repaired or replaced under warranty will be warranted for the remaining warranty period 3 Any warranted pa...

Страница 27: ...harges associated with the inspection and testing of generators which are found not to be a valid warranty claim HOW TO OBTAIN SERVICE To obtain service for this FIRMAN generator you must return it fr...

Страница 28: ...P N 335735001 Rev 00 WWW FIRMANGENERATORS COM Toll Free 1 844 347 6261...

Отзывы: