of reception over distance, but it is possible. Slack loops of extra wire left in the ground
at installation are an example of a condition that would cause an increase of signal and
yet have no problem.
Also, soil condition makes a huge difference in the performance of cable locators.
Basically a circuit is being created from the transmitter, through the cable, out through
the ground and back to the ground stake. Any discontinuity in any of these links will
cause the locator to not work. Be sure your ground stake is secure and in the dirt and
that the transmitter is connected to the cable you want to track.
The soil serves as the return path for the circuit. When using direct connection methods,
you may have to condition dry or sandy soils to increase the conductivity of the soil by
adding a little water at the ground stake.
The best way to really learn the Pro800 is to use it. Set up a test site at your home or
office and get used to how it works. There is no substitute for experience in the art of
locating.
Warranty
– Armada Technologies warranties all products for 12 months from manufacturing defects from the date of retail
purchase. Armada Technologies will repair or replace any component that is returned to Armada Technologies within 12 months
of purchase and does not exhibit signs of abuse or misuse. It is Armada Technologies sole discretion to determine this
condition. Armada Technologies also reserves the right to require a proof of purchase in order to determine date and validity of
purchase.
Batteries are not covered by warranty.
Armada Technologies Equipment Inc.
3596 76
th
St. SE
Caledonia, MI 49316 USA
1-616-536-2038
www.armadatech.com