background image

AC V / DC V 

 

  Caution  

 

When connecting the test leads to the  

circuit or device, connect the black 
lead before the red lead ; when  
removing the test leads, remove the 
red lead before the black lead.

 

Resistance

 

Continuity

 

Diode

 

DCA  Zero

 

ACA / DCA

 

Remove the Jaw out of the conductor. 
Press KEY > 1sec to compensate the  
residual magnetism. 

 

 Caution 

 

Remove Jaw out of the conductor before 
Powering up. The Meter will execute DCA 
Zero during powering up.

 

Priority of function

 

The LCD display shows 
voltage mode when the 
input Terminal is satisfied 
by the following conditions: 

  ACV 1.3V ~ 999.9V 

  DCV 2.1V ~ 999.9V 

         -0.7V ~ -999.9V 

 
The LCD display shows 

 

mode when the input 

terminal is satisfied by the  
following conditions: 

  0 ~ 

 

  ACV 0 ~ 0.9V 

  DCV -0.4 ~ -0.2V 
  DCV 1.0 

2.0V 

 
The LCD display shows 
diode mode when the 
Input Terminal is satisfied 
by the following conditions: 

  DCV 0.4 ~ 0.8V 

 
The LCD display shows 
AC mode when the 
Current Input Jaw is 
satisfied by the following 
conditions : 

  ACA 0.9A ~ 600.0A 

  DCA 0.9A ~ 600.0A

 

 CAT.

.600V 

with respect to  

earth for the jaw. 

Barrier for 

Hand Guard 

 Do not hold  

the meter above  
the Barrier 

 

Input Impedance

 

4K for input voltage up to 30V.  

Impedance increase with input voltage  
to approximate 375K

 

at 750V. 

 

 Warning  

Do not apply more than 1000VDC / 750 
VAC between Tester terminal and earth 
ground.

 

Отзывы: