6
7
MODE SELECTION BUTTON
POWER ON/OFF BUTTON
TIMER BUTTON
REMOTE CONTROL
A
Fan Speed Button
B
Increment Button
(Timer/Temperature)
C
Mode Selection
Button
D
Sleep Mode Button
E
Decrement Button
(Timer/Temperature)
F
Timer Button
G
Power ON/OFF
Button
H
Timer Button
• The remote-control unit requires
2 x 1.5V AAA Alkaline batteries.
• Please remove the plastic isolation piece inside
battery cover plate slot when you use it for first time.
• You can use the remote-control unit when the
distance between the air conditioner and the
remote is less than five meter. Make sure the
deviation of Remote is less than 30°.
• The remote controller has all the same functions
as the buttons on the control panel of the unit.
• To use the remote-control unit, make sure that
unit is plugged into the mains supply, then point
the remote to the sensor located at the control
panel and press the desired button.
• The remote-control unit operating range is 5m.
Make sure there are no obstacles between the
remote and the sensor.
C
A
D
E
H
B
F
G
GBIN004058
GBIN004058
CONTROL PANEL
OPERATION
To power the unit, ensure that the power plug is plugged into an appropriate 240V a.c receptacle and switch
power on at the wall outlet.
Once the power is applied the unit will beep and the display will come up indicating the temperature of the
room, the unit will be in standby mode.
Press the Power ON button and the unit will start operating in the last selected settings.
IMPORTANT! To prolong the life of the compressor, wait for at least 3 minutes before turning on the
unit, after it has been switched off.
Never turn the air conditioner off by unplugging from the mains wall outlet. Always use the
POWER ON/OFF
button to turn off the unit and then wait for few minutes before unplugging the mains power cord.
COOLING MODE
When the unit is default value is cooling mode with 22° and low fan speed.
• Press the
MODE button on the control panel or remote repeatedly until the green LED light next to
the
COOL mode icon lights on the display. This indicates the unit is set in cool mode.
• Press the
UP/DOWN button on the control panel or remote / to set the room temperature as
desired between 16°C to 31°C (60.8°F to 87.8°F). The temperature will increase/decrease by 1°C each
time
UP/DOWN button is pressed.
• Press the
FAN speed button on control panel or remote to change the fan speed from Low to High
and the corresponding LED indicator will light up on control panel.
TIMER ON: Setting only when it is OFF
This function is used to start the unit after a specific time interval.
To set the ON Time:
• To start, ensure the unit is connected to mains supply and the supply switch is turned ON.
• Press the
TIMER button on the control panel or remote and the corresponding green light next
to the Timer Mode icon will glow. Also, the Timer count will be displayed on the display screen.
• Set the time (between 1Hr to 24Hrs) after which you want the unit to be turned ON using the
UP/DOWN button / on the remote or control panel.
• Once the time is selected, the corresponding time will blink for 5 times on the display and the count
is stored in the memory.
• The unit will start operating once the pre-set time is elapsed.
• To cancel the timer setting, press the
TIMER button again and push timer button continuously to
count the timer back to “0”.
TIMER OFF: Setting only when it is RUNNING
This function is used to turn OFF the unit after a specific time interval.
To set the OFF time:
• To turn-off the operating unit after certain duration of time interval press the
TIMER button on the
control panel or remote .
• Set the time after which you want the unit to be turned OFF using the
UP/DOWN button /
on control panel or remote.
• Set the time (between 1Hr to 24Hrs) after which you want the unit to be turned OFF using the
UP/DOWN button / on the remote or control panel.
• Once the time is selected, the corresponding time will blink for 5 times on the display and the count
is stored in the memory.
• The unit will be turned OFF when the pre-set time is reached and will be in standby mode.
• To cancel the timer setting, press the
TIMER button again on the control panel or remote
and by using
UP/DOWN button / bring back the timer count back to “0”.
Note: In an event of power failure the timer needs to the reprogrammed.
Timer function is used to set the ON or OFF time of the unit. This function can be set using the control panel
or remote. The duration of timer is from 1Hr to 24Hrs, the timer is incremented in steps of 1Hr every time.
A
Fan Speed Button
B
Increment Button
(Timer/ Temperature)
C
Mode Selection Button
D
Sleep Mode Button
E
Decrement Button
(Timer/ Temperature)
F
Timer Button
G
Power ON/OFF Button
G
Swing
H
F
D
B
E
A
C
G
The beep sound will be heard every time when the button is pressed on keypad display or remote handset.
FAN MODE
• Press the
MODE button repeatedly on control panel or remote until the green LED light next to the
FAN mode icon lights up on the display.
• Press the
FAN button to change the fan speed from LOW to HIGH and the speed indicator will change
on the display panel to the selected fan speed settings as shown below.
Note: in Fan mode, temperature and sleeping function will be disabled.
DEHUMIDIFYING MODE
• Press the
MODE button repeatedly on the control panel until the green LED light next to the DEHUM
icon lights on the display. Or by press on remote control to active.
• In dehumidifying mode fan speed is pre-set in low mode. Speed button, temperature and sleep
function is not available. The temperature cannot be set either.
Note: Dry mode cannot be used to cool the room, it is ideal to reduce room humidity.
* See water drainage section to drain the condensate (water) in the unit.
SLEEP MODE
• When the unit is operating in cool mode, by pressing the sleep mode button the unit will enter sleep mode.
• During sleep mode, the fan speed will be adjusted to low speed and the corresponding low speed icon
will light up on the keypad display and the speed can’t be adjusted during this time.
• The set temperature will increase by 1° after one hours since the time unit has entered in sleep mode.
The unit will continue to operate at the new set temperature for next one hours and then again increase
the set temperature by 1°. The final setting temperature will be the same after unit automatically increase
set temperature twice.
• Note: Sleeping mode is invalid under dehumidifying and fan mode. Under water drainage is full,
machine will change to standby mode and sleeping mode will be cancelled.