10
11
TROUBLE SHOOTING
GBIN004060
GBIN004060
PROBLEM
CAUSE
SOLUTION
The unit does not come ON.
Unit not plugged in.
Make sure the plug is pushed in
completely and power switch is
switched ON.
Internal safety device has operated.
Wait for 30mins and try again.
Wall socket is not working.
Check with another working
wall socket.
The overflow indicator displays “FL”.
Empty the water inside the tank.
Unit works for a short
time only.
Bends or kinks in the air exhaust hose.
Position the hose properly, keeping it
as short as possible with no bends.
Air outlet/inlet grilles are blocked.
Visual inspect the unit to make sure
no foreign material is obstruction the
airflow.
Unit does not cool the room.
Room size too large.
Unit is suitable for a room size of
16m
2
with a standard ceiling height
of 2.4m.
Direct sunlight onto the unit.
Close curtains and pull down blinds.
Windows or doors open.
Close doors and windows.
Another heat source in the room.
Eliminate all other heat sources.
Outlet duct venting the hot air properly.
Adjust the hose properly so that
there is no back flow of hot air in
the room.
Room temperature below your
selected temperature.
Adjust the room temperature.
Unit is too noisy.
Unit placed on a hard surface
causing it to vibrate.
A soft carpeted surface may absorb
excessive vibration.
The unit does not operate
for about three minutes after
it is restarted.
This is for the safety of the compressor
which prevents the unit from being
restarted until three minutes have
elapsed since it was last turned off.
This is part of normal operation.
1.
Screw off the drain cap and drain the water in the water tray to another vessel that holds water.
Note: The tilt angle of the unit shall not be greater than 30 degrees.
2.
Start the unit, turn the mode to the low fan speed state of the air supply mode, keep this state for half a
day and dry the interior of the unit to prevent mold.
3.
Turn off the unit, unplug the power plug, wrap the power cord around the wire-winding post, install the
water plug and drain cap.
4.
Remove the exhaust hose assembly and keep it in a secure place.
5.
Pack the air-conditioner properly with soft plastic bag, put the unit in a dry place & take appropriate
dust-proof measures, and keep the unit out of the reach of children.
6.
Take out the batteries of the remote control and keep them in a secure place.
Note: Ensure that the unit is put in a dry place. All accessories of the unit should be stored
in a secure place.
END OF SEASON STORAGE
MAINTENANCE
Clean the surface of the unit with wet soft cloth. Do not use chemical solvents such as alcohol and gasoline;
otherwise, the surface of the air conditioner may be damaged and even the whole unit may be damaged.
If the filter screen is clogged with dust, and the effectiveness
of the air conditioning is reduced, be sure to clean the filter
screen once every two weeks.
Clean the upper filter screen frame:
1. Unscrew the screw provide in the middle of the EVA filter.
Clasp the wedging block of the EVA filter screen frame
with hands. Force down from the outside to remove the
EVA filter screen frame as shown.
PLEASE NOTE: When taking out the filter frame, the
force shall be applied evenly on the wedging block.
Be sure to take out the filter frame first and then take
out the filter mesh.
2. Use vacuum cleaner to remove the dust from the filter
frame. If the frame is very dusty place it in the warm water
under 40°C or 104°F to which neutral detergent is added
for cleaning and then dry them in the shade. Rinse the
filter and dry it in a shaped place.
NOTE: Do not damage the mesh fabric on the filter
frame and filter mesh.
Prior to maintenance and servicing of the unit, turn off the power and unplug the plug.
SURFACE CLEANING
CLEAN THE FILTER SCREEN
Remove
Screw
EVA
Filter