5
6
Arlec guarantees this product in accordance with the Australian Consumer Law.
Arlec also warrants to the original first purchaser of this product (“you”) from a retailer that this
product will be free of defects in materials and workmanship for a period of 12 months from the date of
purchase; provided the product is not used or installed other than for the purpose, or in a manner not
within the scope of the recommendations and limitations, specified by Arlec, is new and not damaged
at the time of purchase, has been properly installed by a licensed electrician or contractor who is
licensed to install electrical products in the place in which the product was installed and in accordance
with Arlec’s installation instructions, has been maintained in accordance with the recommendations
specified by Arlec, has not been subjected to abuse, misuse, neglect or damage, has not been
modified or repaired without the approval of Arlec and has not been used for, or installed in premises
which are used for, commercial purposes (“Warranty”).
If you wish to claim on the Warranty, you must, at your own expense, return the product or that part
of the product which you believe is defective in materials and workmanship, and provide proof of
original purchase, your name, address and telephone number and a certificate of installation or other
document required by law for the installation of electrical products in the place in which the product
was installed issued by the licensed electrician or contractor who installed the product, to Arlec at the
address below within 12 months from the date of purchase. Please note that the Warranty does not
cover removal or re-installation of the product or that part of the product which you believe is defective.
Arlec will assess any claim you may make on the Warranty in the above manner and if, in Arlec’s
reasonable opinion, the Warranty applies, Arlec will at its own option and expense replace the
product (or part of the product) with the same or similar product (or part of the product) or repair
the product (or part of the product) and return it to you or refund the price you paid for the product.
Arlec will bear its own expenses of doing those things, and you must bear any other expenses of
claiming on the Warranty.
The Warranty is in addition to other rights and remedies you may have under a law in relation to the
product to which the Warranty relates.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law.
You are entitled to a replacement or refund for a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced
if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Arlec Australia Pty. Ltd. ACN 009 322 105 (“Arlec”) gives the Warranty.
Arlec’s telephone number, address and email address are:
Customer Service: (03) 9982 5111
Building 3, 31 – 41 Joseph Street, Blackburn North, Victoria, 3130
Blackburn North LPO, P.O. Box 1065, Blackburn North, 3130
Email: [email protected]
Warranty
4
Should a problem still exist after following all of the above user hints, contact your nearest Arlec Service Department.
problem
possible cause
suggested remedy
Light does not switch ON when there is
movement in the detection area.
1. No main power.
Check all connections, and fuses/switches.
2. Globe faulty or missing.
Check. Replace.
3. Wiring incorrect.
Re-check.
4. Nearby lighting is too bright.
(A) Re-direct sensor or relocate unit
(B) Gradually turn light level control
anti-clockwise.
5. Controls set incorrectly.
Re-adjust sensor angle.
6. Sensor positioned in
wrong direction.
Re-direct sensor by tilting.
Light switches ON for no
apparent reason.
1. Heat sources such as air con,
vents, heater flues, or very cold
objects are near sensor.
Adjust direction of sensor head from these
sources by tilting.
2. Animals/birds e.g. possums.
Probably unavoidable but relocating
sensor may help.
3. Interference from ON/OFF switching
of electric fans or lights on the
same circuit as your Security
Sensor. (This problem does not
always occur but a faulty switch or
a noisy fluorescent light may cause
your lights to switch ON.)
Should the false triggering become
troublesome consider:
(A) Replacing a faulty switch.
(B) Replacing noisy fluorescent tubes
and/or starters.
(C) Connecting the Security Sensor to a
separate circuit. (In most cases where
one or more of the above suggestions
have been carried out, false triggering
has been reduced.)
4. Interference from power surges,
mobile phones, CB’s, Taxis, etc.
Nil
5. Heat source, BBQ, etc.
Re-direct sensor by tilting.
6. Reflection from swimming pool or
reflective surface.
Re-direct sensor by tilting.
Poor sensitivity and range
1. Movement directly to or away from
sensor
Re-direct sensor by tilting. (Refer to page 2).
2. Higher ambient temperature
Nil.
Note: All passive infra red detectors are more
sensitive in cold weather than warm weather.
Light remains ON
1. Sensor is in automatic override
continuous ON mode
Switch sensor OFF for 20 seconds at wall
switch, and then return to ON position.
2. Time is set too long
Reduce time by turning clockwise.
3. Wiring is incorrect
Re-check wiring.
trouble shootiNg guide
CPIN002323/2
CPIN002323/2
PVC electrical tape
Figure 5.
To reduce the 150° wide angle detection area,
stick PVC electrical tape on the left, right or both
sides of the sensor lens. This will reduce 150°
detection in extremities of area to be scanned.
After adding PVC tape some further adjustment
of light level control maybe necessary.
Detection range
12 metre at 180°
scan (Approx)
Time Adjustment
10 seconds to 7 minutes
(Approx)
Detection Circuitry
Passive controlled
infra red motion sensor
Power Required
230-240 volt, 50Hz,
6 watt Consumption
Rating
1000 watt max
Incandescent load,
500 fluorescent load.*
Weatherproof Rating IP44
*Power factor correction capacitors must be
removed from fluorescent and connected at
mains input of sensor.
reduciNg detectioN area