10 PROBLEM GUIDE
Breakdown
Possible cause
Solution
It counts too fast or too slow.
- wrong calibration
- air inlet
- blocked gears
- calibrate the meter (please refer
to Section 6.2.).
- look for and repair the possible
leaks or air inlets in the system.
- clean and replace the gears.
Low flow
- impurities
in
the
measuring
chamber
- clean the measuring chamber.
The display is not switched on.
- dead battery
- replace the battery (please refer
to Section 6.3.).
The litres are passing, but the
numeration does not count.
- dead battery
- REED problem
- replace the battery (please refer
to Section 6.3.).
- call the TECHNICAL SERVICE.
Loss of liquid
- damaged joints
- replace the joints.