The sensor head has to be properly
tightened
During the sensor installation please check the
head and the four screws for proper tight.
Removal during maintenance
If the application requires removal of the sensor
for periodic maintenance, it is recommended to
install a bypass section as the drawing below.
All MAGE1 sensors are supplied with a built in earthing electrodes that are sufficient for all applications with
metal pipes and tanks. However on applications where all pipes and tanks are manufactured from plastic, it
is recommended that earthing rings are also installed to ensure the maximum resistance of the sensor to
earth is <1 ohm.
2.2. Dry liner
Flowmeters with a Hard Rubber liner can show incorrect readings during the first 2-3 days after installation.
This is due to the fact that the time needed for transport and the time before installation is long enough for the
liner to dry out and thus it changes shape/size. This change, in effect, affects reading accuracy. Simply be
keeping the meter wet, this problem solve itself within 2-3 days and no other action is required at all.
Conductive (metal) pipe
Non-conductive (plastic, lined) pipe