Agrimag User Guide
8
V1.9 26-4-2019
Total Volume
This is the total volume counter. Negative flow is not counted.*
Batch Volume
This counter works the same way as Total Volume. Both counters are independently clearable.*
*
If value of any Volume counter higher than 4 000 000 m3, than value of Volume show only in m3 unit. If value of any Volume counter higher than
999 999 999 m3, then this Volume will be reset to 0
3.2. Errors and Warnings
That is a list of the possible errors for Agrimag/AgrimagP:
Low Battery status
If the Low Battery appears on the screen, we recommend that the existing batteries are replaced with new
batteries. Note: Applies for battery operated version only.
Empty Pipe
If the Empty pipe appears on the screen there is no medium in the pipes, the meter is preserving batteries
until the pipes are full again.
Excitation
Coils interrupted or disconnected.
AD-converter
AD converter fault.
Note: The error disappears when the cause of it is fixed. You can see the measurement when you touch
any of the controls.
Overloaded
That error occurs when the measured flow is bigger than 1.2 * Flow Qn. Depending on the size:
Size 25mm: 20.76m3/h
Size 50mm: 81.6m3/h
Size 80mm: 211.2m3/h
Generally that error will occur when the AD converter is overloaded. It can be because on the electrodes
are very big voltage or because the flow is really that high.