3

Operating Instructions and Parts Manual 

29

00 CFM 3 SPEED  

EVAPORATIVE COOLER

2/17

AZ Air  Coolers LLC

ASSEMBLY INSTRUCTIONS

Coolers are pre-assembled and ready to operate. Simply remove the 

packaging and then carefully remove the unit from the box. 
Install the casters. Lock the 2 locking wheels before filling and turning on 

fan to keep the cooler from moving from the air velocity.

NOTE: 

The media pad will have a slight odor when it is new. This is 

normal. It will dissipate after a period of time depending on the use time. 

Draining the tank often during the break in period will help speed this up.

OPERATING INSTRUCTIONS

1.  Your cooler must be positioned in front of an open window or door if it

is to operate effectively.

2.  Always ensure that there is another open window or door through

which the air can exhaust from the room.

3.  Ensure the filter is kept clean throughout the summer season.
4.  At the end of each day run your cooler on FAN ONLY for 30 minutes to

dry out the filter.

5.  Prior to putting your cooler away for winter, always:

a. Drain the tank and wipe out clean.
b. Clean the filter.
c.  Re-assemble and run on FAN ONLY for 30 minutes to dry out the filter.

6. Having completed assembly of your cooler, position the unit with

its back to an open window or door. This will allow fresh air to be

drawn through the cooler and exhausted from the room. Constant

air change is essential and part of the fresh air benefit from

evaporative air cooling.

7.  Remember your cooler has been designed to operate even if it runs

out of water. No damage will be caused to the pump if cooler runs out

of water.

FILLING COOLER OR CONNECTING TO WATER SUPPLY

Move the cooler to an area where it can be filled.

MANUAL FILL

The cooler can be filled via the front fill door by hose or bucket. Using the 

water fill indicator to monitor water level, simply depress the fill door and the 

spring lock will release and open it. To close, simply push it closed and locked.

AUTO FILL CONNECTIONS

Connect to a water supply using a garden hose or coil hose (supplied 

by customer), or a direct water line. (Parts for direct connection can be 

obtained at any hardware store.) Simply attach hose adapter (supplied 

with cooler) to the float valve nipple protruding from cooler. Verify water 

tight connections by visually examining the hose connection.

CAUTION

Water inlet pressure should be limited to a maximum 50 PSI. If valve is 

overcome, install a pressure reducer (25 PSI) on nipple first. (It can be 

obtained at hardware stores in irrigation section.) Hose bib needs only be 

cracked open slightly to supply water to float valve and the cooler only 

needs to be about half filled when in auto fill configuration. The float is 

already set to that level.

USING THE CONTROL SWITCHES MECHANICAL VERSION
ROTARY SWITCH/MOTOR SPEED 

4 POSITIONS: (CLOCKWISE FROM OFF)

0. Off

2. Medium fan

1. Low fan 

3. High fan

Left rocker switch: 

Controls water pump on or off.

Middle rocker switch: 

Controls fan oscillation.

POWER SWITCH

Controls power to the main controls, it will be lit when it is in the ON position, 

dark when OFF. When it is OFF the other switches will not function.

NOTE: 

The pump circuit is equipped with an encapsulated pump cut-off 

float switch mounted in the cooler. If the cooler is low on water, the water 

pump will not operate and the pump switch will be interrupted.

MAINTENANCE

WARNING

: Do not remove the back panel with the cooler running.

NOTE: 

For best operation and long useful life the following maintenance 

and cleaning procedures should be followed.

CLEANING COOLER AND PADS

At regular intervals the cooler should be shut down and disconnected 

from power supply. The water tank should be drained of dirty water and 

sprayed out with fresh water and refilled. The more you do this the better 

it will work and less calcium will develop on pads or other surfaces. 

You may spray through the cooling pads to wash them out and allow 

water to deposit in the tank to be drained away. The removable panel 

and media pad can be sprayed out on the ground to clean pad. Use light 

pressure when spraying pads. NEVER spray pads with water while cooler 

is operating and fan is running. This can cause damage to motor and will 

void the warranty.

REMOVAL OF THE BACK PANEL

WARNING

: Disconnect power supply before this procedure.

1.  Unscrew the screws at top of back panel (3).
2.  Lift Panel up and pull out at the bottom. 
3.  Slide the panel out of the cabinet. 
4.  You will now have access to the pump, float valve and the water

distributer spreaders.

DRAINING THE COOLER TANK

Unscrew drain cap from drain assemble and drain away water. You may tip the 

unit carefully to the drain side to help drain all the water out.

REMOVAL AND REPLACEMENT OF COOLING MEDIA

The cooling pads are made from a special resin impregnated craft paper 

specially designed for evaporative cooling. They will last many years if 

maintained properly and water quality is maintained. It is not necessary to 

remove the pads to clean them.
Inspect the pads for deposits of calcium on the air entering side. If the flute 

cells are clogged or the pad is very heavy it may be time to change the media. 

New media can be purchased where you bought the cooler. Follow these steps 

for replacing the pads.

Pump

Swing

On/Off

0

1

2

3

AZ39MA1

AZ39MB1

Содержание KUUL KUBE AZ39MA1

Страница 1: ...This product is designed for certain applications only OEMTOOLS cannot be responsible for issues arising from modification We strongly recommend this product is not modified and or used for any application other than that for which it was designed If you have any questions relative to a particular application DO NOT use the product until you have first contacted customer service to determine if it...

Страница 2: ...ns that may occur The operator must understand that common sense and caution are factors which cannot be built into this product but must be supplied by the operator DISPOSAL At the end of the useful life of the Evaporative Cooler dispose of the components according to all state federal and local regulations PURPOSE Evaporative cooling works on the principle of heat absorption by moisture evaporat...

Страница 3: ...Hose bib needs only be cracked open slightly to supply water to float valve and the cooler only needs to be about half filled when in auto fill configuration The float is already set to that level USING THE CONTROL SWITCHES MECHANICAL VERSION ROTARY SWITCH MOTOR SPEED 4 POSITIONS CLOCKWISE FROM OFF 0 Off 2 Medium fan 1 Low fan 3 High fan Left rocker switch Controls water pump on or off Middle rock...

Страница 4: ...TIES OF MERCHANTABILITY AND FITNESS This warranty gives you specific legal rights and you may also have other rights which vary from state to state Don t forget to register your new KUULKUBE product at www KUULKUBE COM 1 With access panel removed simply pull off the pad retainer disc from the pad pin 2 With disc removed remove the pins from the pads and carefully remove pads from the fixed side mo...

Отзывы: