1.2 Components
The top panel (1) is opened by lifting the front edge. Under this are the ash hatch (2)
and the filler hatch (17) for the pellet hopper.
The front (5) is opened to reach the door (7). The door is unlocked with the enclosed
handle and it opens forwards, towards the floor. The burner housing (8) is located in the
hearth and is accessible when the door has been opened. It is installed with four screws
on the rear of the stove body. The burner (9) sits loose in the burner housing. The firing
element (10) is located in the burner housing behind the burner.
The firing element gives off the heat required to ignite the fuel. The flame sensor (11) is
beside the ignition unit and indicates whether there is flame in the burner. The ash box
(12) is inserted in the bottom of the hearth, under the burner housing. It can be removed
when the door has been opened.
The combustion fan (13) is placed on the rear of the burner housing and provides the
burner with air for combustion. If the stove is connected to the flue Drag, the fan is
replaced by a hose, which is connected to the wall lead-in. The control circuit board (15)
is placed inside the stove and it is powered by an electronic transformer that supplies
12V-voltage to the electronics and control and sensors. The hot air fan (16) is located
inside the stove and sucks air from the rear of the stove, which is then heated up in the
combustion chamber and smoke tubes (4) and expelled through holes, partly in the back
plate and partly in the front.
The pellet hopper (17) is filled through the filler hatch (18). The hatch is locked with a
knob. The pellet feeder (19) sits in the bottom of the pellet hopper and it consists of a
slowly rotating screw. The patented design means that pellets cannot stick in the feeder.
Safety thermostats (20) are mounted on the pellet hopper’s right side (trip at 85˚C) and
the ash box (trips at 204˚C).
The stove must not be modified and only spare parts recommended by the
manufacturer may be used.