PELLET STOVE KMP EKERUM / NEPTUNI
ARITERM SWEDEN AB
Installation Instructions -
2011.08.19
- 16
/24
3.6.1 Fault tracing and remedy
In the event of an unsuccessful start attempt or
operating stoppage, the burner crucible must
always be emptied!
The stove does
not start, nothing
displayed.
• The cable is not connected.
• No voltage at the socket.
• Stove fuse blown.
• The cable between the control
panel and the control circuit
board is not correctly
connected.
Connect to earthed 230V socket.
Check the fuse.
Replace the fuse, see section 4.7.
Check that the lead is connected
at both ends.
The stove is in
”Standby” mode.
• The room temperature exceeds
the set stop
temperature.
• The room temperature must
exceed 5˚C for the thermostat
to work.
Set the desired stop temperature.
Increase ”Stop T” above 30˚C to
start in ”On-mode”. When the
room temperature has exceeded
5˚C, adjust the desired stop
temperature.
Condensation leaks
from the stove’s flue
connection.
• Flue smoke too cold for the
chimney.
Increase the output by adjusting
the amount of fuel and air.
Deactivate low output.
Insulate the chimney.
Install condensation trap.
Smoke odour.
• Blocked smoke access.
• Contaminated convection
ducts.
• Negative pressure in the house.
Clean the stove see 3.4.
Clean the stove see 3.4.
Ensure that the stove has the
necessary ventilation.
The ash becomes a
hard cake.
• Incorrectly adjusted fuel or air
amount.
• The fuel has a too low ash
melting temperature.
See Menu.
Contact the fuel supplier.
Black ash or soot on
the glass.
• Too much ash in the crucible or
blocked vent.
• Dirty combustion fan.
• Incorrectly adjusted fuel or air
amount.
Clean the burner crucible.
Clean the combustion fan.
See Menu.
Fault
Cause
Action
Fault
Cause
Action