background image

GB

2

!

 Before operating your new appliance please read this

instruction booklet carefully. It contains important information
for safe use, installation and care of the appliance.

!

 Please keep these operating instructions for future

reference. Pass them on to possible new owners of the
appliance.

Positioning

!

 Keep packaging material out of the reach of children. It

can become a choking or suffocation hazard (

see

Precautions and tips).

!

 The appliance must be installed by a qualified professional

according to the instructions provided. Incorrect installation
may cause harm to people and animals or may damage
property.

!

 This unit may be installed and used only in permanently

ventilated rooms in accordance with British Standard Codes
Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891
Current Editions. The following requirements must be
observed:
• The room must be equipped with an air extraction system

that expels any combustion fumes. This may consist of a
hood or an electric fan that automatically starts each time
the appliance is switched on.

• The room must also allow proper air circulation, as air is

needed for combustion to occur normally. The flow of air
must not be less than 2 m

3

/h per kW of installed power.

The air circulation system may
take air directly from the outside
by means of a pipe with an inner
cross section of  at least 100 cm

2

;

the opening must not be
vulnerable to any type of
blockages.

The system can also provide the
air needed for combustion
indirectly, i.e. from adjacent rooms
fitted with air circulation tubes as
described above. However, these
rooms must not be communal
rooms, bedrooms or rooms that
may present a fire hazard.

• Liquid petroleum gas sinks to the floor as it is heavier

than air. Therefore, rooms containing LPG cylinders must

also be equipped with vents to allow gas to escape in the
event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or stored
in rooms or storage areas that are below ground level
(cellars, etc.). It is advisable to keep only the cylinder
being used in the room, positioned so that it is not
subject to heat produced by external sources (ovens,
fireplaces, stoves, etc. ) which could raise the
temperature of the cylinder above 50°C.

Fitting the appliance

Gas and mixed hobs are manufactured with type X degree
protection against overheating. The following precautions
must be taken when installing the hob:
• Kitchen cabinets adjacent to the appliance and taller

than the top of the hob must be at least 600 mm from the
edge of the hob.

• Hoods must be installed according to their relative

installation instruction manuals and at a minimum
distance of 650 mm from the hob.

• Place the wall cabinets adjacent to the hood at a

minimum height of 420 mm from the hob (

see figure).

If the hob is installed beneath a
wall cabinet, the latter must be
situated at a minimum of 700 mm
above the hob (

see figure).

• The installation cavity should have the dimensions

indicated in the figure.

Fastening hooks are provided, allowing you to fasten the

hob to tops that are between 20 and 40 mm thick. To
ensure the hob is securely fastened to the top, we
recommend you use all the hooks provided.

555 mm

55 mm

475 m

m

Hook fastening diagram

Hooking position

Hooking position

for top

 H=20 mm

for top 

H=30 mm

Installation

Enlarging the ventilation slot
between window and floor.

Adjacent
Room

Room to be
Vented

A

Examples of ventilation holes
for comburant air.

In a chimney stack or branched flue. 
(exclusively for cooking appliances)

Directly to 
the Outside

600mm min.

600mm min.

700mm min.

Содержание PH640MST NG

Страница 1: ...of the appliance 6 Overall view Start up and use 7 Practical advice on using the burners Precautions and tips 8 General safety Disposal Maintenance and care 9 Switching the appliance off Cleaning the...

Страница 2: ...o the floor as it is heavier than air Therefore rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak As a result LPG cylinders whether partiall...

Страница 3: ...ly cord must be positioned so that it does not reach a temperature in excess of 50 C above room temperature at any point Before making the actual connection make sure that The fuse and electrical syst...

Страница 4: ...zzle characteristics 3 Reassemble the parts following the above procedure in the reverse order 4 Once this procedure is finished replace the old rating sticker with one indicating the new type of gas...

Страница 5: ...uced Rapid RR 100 9 0 80 8 3 129 Semi Rapid S 75 5 5 64 6 0 110 Auxiliary A 55 3 5 50 3 3 80 Triple Crown TC 130 15 0 105 15 0 175 Total Thermal Power MJ h 33 0 32 6 Supply pressures Nominal kPa Minim...

Страница 6: ...e burner to cook with Control Knobs for GAS BURNERS adjust the power or the size of the flame GAS BURNER ignition enables a specific burner to be lit automatically SAFETY DEVICE stops the gas flow if...

Страница 7: ...the switch the symbol is located near each knob To light a burner simply press the corresponding knob all the way in and then turn it in the counter clockwise direction to the High setting keeping it...

Страница 8: ...circumstances should you attempt to repair the appliance yourself Repairs carried out by inexperienced persons may cause injury or further malfunctioning of the appliance Contact a Service Centre see...

Страница 9: ...burners should be washed frequently with warm water and soap and any burnt on substances removed For hobs which ligth automatically the terminal part of the electronic instant lighting devices should...

Страница 10: ...liance You pressed the knob all the way in You keep the knob pressed in long enough to activate the safety device The gas holes are not blocked in the area corresponding to the safety device The gas h...

Страница 11: ...GB 11...

Страница 12: ...GB 12 08 2010 195020547 08 XEROX FABRIANO...

Отзывы: