Y O U ’ L L   N E E D

Assorted Torx Drivers
Phillips Head Screwdriver

Coff ee Center

Removing the Coff ee Center Chassis

T E C H N I C A L   E D U C AT I O N

G R O U P   P R E S E N T S  

M O D E L S

MCA15NA Ariston™ Coff ee Center
MCA15APNA Ariston™ Coff ee Center

Q U E S T I O N S ?

 

Westland Sales
15650  SE 102nd Ave. (PO BOX  427)
Clackamas, OR 97015

Telephone: 877-356-0766
Service Fax: (503) 722-9202
Service E-mail: 
[email protected]

Re-mounting the Flow Meter Housing

Make sure the Plunger 
located behind the Flow 
Meter Housing is properly 
aligned.

Make sure 
the Flow 
Meter is 
properly 
secured in 
the Flow Meter Housing.

To re-seat the Flow Meter 
Housing in the Coff ee 
Center, fi rst align the 
Groove in the Flow Meter 
Housing

 

with the Plunger.

Push the housing back 
while making sure the 
housing edge is properly 
seated on Ledge next to 
Plunger. Secure rear of 
Flow Meter Housing by 
lifting upward to snap the 
clips into place 

(see Figure 

4-1)

.  Finally, close the 

Access Door.

5.

6.

7.

8.

Plunger 

Aligned

To verify the ‘CLOSE DOOR’ Fault is cleared, place a cup under 
the steam spout and press the Water        key. Dispense at least 
16 oz. of water.  Next, place a cup under the brew spout and 
press the Large Coff ee        key to brew a cup of coff ee. 

9.

NOT Aligned 

Page 2 of 2 

Ledge

Groove

Plunger 

If the fault has cleared, reassemble the unit in reverse order of 
disassembly. 