Problem:  

Coff ee Center displaying a ‘CLOSE DOOR’ fault

Solution:  

Re-mount the Flow Meter Housing

Y O U ’ L L   N E E D

Assorted Torx Drivers
Phillips Head Screwdriver

Coff ee Center

Removing the Coff ee Center Chassis

T E C H N I C A L   E D U C AT I O N

G R O U P   P R E S E N T S  

©   C o p y r i g h t   2 0 0 6 ,   W e s t l a n d   S a l e s ,   C l a c k a m a s ,   O R   9 7 0 1 5  

M O D E L S

MCA15NA Ariston™ Coff ee Center
MCA15APNA Ariston™ Coff ee Center

Q U E S T I O N S ?

 

Westland Sales
15650  SE 102nd Ave. (PO BOX  427)
Clackamas, OR 97015

Telephone: 877-356-0766
Service Fax: (503) 722-9202
Service E-mail: 
[email protected]

Re-mounting the Flow Meter Housing

With unit OFF and unplugged 
from power and water sources, 
remove coff ee center chassis

 

(see supplemental instructions)

Next, squeeze button to open  
Access Door.

Remove the two Size 10 Torx 
Screws that secure the Rear 
Panel to the back of the unit.

Remove the Rear Panel by 
pulling upwards then toward 
the rear of the unit.

1.

2.

3.

Harness Clip

Hose

Locate Flow Meter Housing. Remove wire harness from 
Harness Clip. Remove Flow Meter Connector from Flow Meter. 
Remove hose from left side of Flow Meter Housing.

4.

Page 1 of 2 

Flow Meter

Housing

Flow Meter

Connector

Access Door Button

Fig. 4-1

Clip

Clip