GB
7
A
A
R
S
S
FTGHG 751 D/A LPG
Connecting a flexible jointless stainless steel pipe to a threaded
attachment
Suitable for connection with a flexible hose assembly.The flexible hose
assembly must be certified to AS/NZS 1869 class B or D, be of appropriate
internal diameter, be kept as short as possible (not to exceed 1200 mm),
must not be in contact with the floor or any hot or sharp surfaces. The hose
assembly must not be subject to strain, abrasion, kinking or deformation.
!
Ensure pipes do not touch any moving parts and is not compressed.
!
Only use pipes and seals that comply with current national regulations.
Checking the tightness of the connection
!
When the installation process is complete, check the pipe fittings for leaks
using a soapy solution. Never use a flame.
Operation of the appliance must be tasted by the installer before leaving.
Check all burners flames are blue in colour, stable and completely ignite at
both high and low flame settings with no appreciable yellow tipping, carbon
deposition, lifting, floating back or objectionable odour.
Test burners individually and in combination.
For other minor adjustments or if the appliance does not
perfrom correctly; contact Arisit Pty Ltd 1300 762 219
width
height
depth
Electrical
connections
Dimensions
(cm)
DATA PLATE
240 V
Hob 60 Hob 75 Hob 90
60
4,15
51
75
4,15
51
90
3,3
51
Table 1
Fast (R)
Semi Fast (S)
Auxiliary (A)
Burner
Diameter
(mm)
Gas
Consumption
(MJ/h)
157
132
110
8.5
5.5
3.0
0.80
0.65
0.48
(mm)
4.2
2.9
2.7
Burner and nozzle specifications
Universal LPG
(2.75 kPa)
Adjusting the burner’s
(Primary air)
Place the supplied duplicate data plate to a suitable adjacent surface or within the instruction manual for the future reference
Injector