GB
38 /
3. SIMPLE MAINTENANCE
WARNING:
- Unplug the appliance or switch o
ff
the dedicated switch be-
fore performing any operations (risk of personal injury from
electrocution).
- Do not touch the air conditioning unit with wet hands (risk of
personal injury from electrocution).
- When cleaning the appliance, do not climb onto a table or
unstable chair (risk of personal injury due to falling from a
height).
- When removing
fi
lters, take care not to touch any metal
parts, especially the heat exchanger inside the internal unit
(risk of personal injury from cuts).
3.1 Cleaning the
fi
lters
Cleaning the
fi
lters regularly is essential for optimal performance
of the air conditioning unit. For domestic settings, we recommend that
fi
lters be cleaned fortnightly. The need to clean the air
fi
lters or replace
the special
fi
lters is however indicated on the display, on the basis of the
hours that the air conditioning unit has operated.
Dust
fi
lters
By pulling upwards carefully unfasten the
fi
lter on the top of the
internal unit (
fi
g. 1). Then remove it by pulling towards you (
fi
g. 2).
Clean them using a vacuum cleaner or wash them in lukewarm
water and neutral detergent. Make sure you dry them thoroughly
before replacing them. Do not leave them exposed to sunlight. Do
not operate the air conditioning unit without the air
fi
lters.
Air treatment
fi
lters
Open the front panel and remove the dust
fi
lters as described
above. Remove the air treatment
fi
lters from their seat as illus-
trated in
fi
g. 3.
- Platinum
fi
lter
These
fi
lters must be replaced once they are no longer capable
of performing their task (approx. 24 months).
- Aromatherapy
The
fi
lter uses the air
fl
ow passing through the air conditioning
unit to di
ff
use the desired fragrance within the room. To add
the fragrance, remove the
fi
lter as described above; pour the
desired amount of scent onto each end of the
fi
lter and at its
centre; position the
fi
lter back in its seat.
The ideal amount of scent depends on the type of fragrance
used and individual user preferences: we recommend starting
with small amounts (e.g. 5 ml).
Note: use essential oils speci
fi
cally designed as room fragrances.
3.2 Cleaning the air conditioning unit
Clean the Internal Unit and remote control, if necessary, using a
cloth moistened with lukewarm water (no hotter than 40°C) and
mild soap; do not use solvents or aggressive detergents, insecti-
cides or spray cleaners (risk of damaging or corroding the plastic
parts of the appliance).
Take extra care when cleaning the front panel, as it is very easy
to scratch.
If the External Unit battery is clogged up, remove all leaves and
deposits and then wash o
ff
all dust with a water jet or some water.
(FIG. 1)
(FIG. 2)
(FIG. 3)
EXTERNAL UNIT BATTERY
FILTERS
Содержание DUAL 50 XD0C-O
Страница 2: ......
Страница 175: ... 175 ...