background image

ahl-631 Revision Date 2.14.22

15

1

2

3

4

5

6

6

9

10

10

11

12

13

8

8

14

7

7

15

15

WHL-026-A

06/03/21

PARTS FOR UNITS WITH BOLT-ON T-STAT BRACKETS ONLY-NOT SHOWN

ITEM#

DESCRIPTION

 PART #

1

JUNCTION BOX COVER (w/SCREWS)

6060P-983

2

THERMOSTAT - UPPER

6060P-1008

THERMOSTAT - UPPER ("U" MODELS ONLY)

6060P-001

3

THERMOSTAT - LOWER

6060P-1009

THERMOSTAT LOWER  ("U" MODELS ONLY)

  6060P-002  

4

THERMOSTAT PROTECTIVE COVER -UPPER

6060P-994

THERMOSTAT PROTECTIVE COVER -UPPER (U-MODELS ONLY)

6060P-634

5

THERMOSTAT PROTECTIVE COVER-LOWER

6060P-952

THERMOSTAT PROTECTIVE COVER-LOWER (U-MODELS ONLY)

6060P-636

6

ACCESS PANEL

6060P-187

7

SCREWS - ACCESS PANEL

6075P-006

8

MOUNTING BRACKET

6060P-955

MOUNTING BRACKET  ("U" models only)

6060P-956

9

ELECTRIC ELEMENT - 3000W

6060P-939

ELECTRIC ELEMENT - 4500W

6060P-938

ELECTRIC ELEMENT - 5500W

6060P-937

10 DRAIN VALVE 

6070P-009

11 DIP TUBE - 40 GAL                                                                              

DIP TUBE - 52 GAL.

6060P-1034  

6060P-1035

12 NIPPLE/HEAT TRAP

6060P-1038

13 TEMP/PRESSURE RELIEF VALVE

TP1000

14 JUNCTION BOX COVER W/ KNOCKOUTS (W/SCREWS)

6060P-982

15 PROTECTIVE INSULATION

6060P-965

16 THERMOSTAT MOUNTING BRACKET-BOLT-ON

6060P-633

17 SPACER

6060P-979

18 NUTS

6060P-935

19 ELEMENT PROTECTIVE COVER

6060P-997

Figure 8 - Replacement Parts - Staged Operation

Part 9 - Replacement Parts

Содержание ARIER040C2X045N

Страница 1: ...r updates without notice and will not be held liable for typographical errors in literature NOTE TO CONSUMER PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE 272 Duchaine Blvd New Bedford MA 02745 www ariston com ahl 631 Revision Date 2 14 22 The surfaces of these products contacted by potable consumable water contain less than 0 25 lead by weight as required by the Safe Drinking Water Act Sectio...

Страница 2: ...g details 3 Install or locate this water heater only in accordance with the provided installation instructions 4 Use this water heater only for its intended use as described in this manual 5 Do not operate this water heater if it has been damaged or dropped 8 This water heater should be serviced only by qualified service personnel Contact the water heater installer or a qualified service agency fo...

Страница 3: ...ting 14 Part 9 Replacement Parts 15 Limited Warranty 16 Customer Installation Record Form 18 Do not use this water heater for anything other than its intended purpose as described in this manual Doing so could result in property damage and WILL VOID product warranty A When Servicing the Water Heating System NOTE When inquiring about service or troubleshooting reference the model and serial numbers...

Страница 4: ...m Operating Conditions Ensure ambient temperatures are higher than 32oF 0oC and lower than 104oF 40oC Avoid continuously high levels of humidity Never close existing ventilation openings NOTE When installing in a zero clearance location it may not be possible to read or view some product labeling It is recommended to make note of the water heater model and serial number NOTE A combustible door or ...

Страница 5: ...ional more frequent maintenance may be required If you suspect that your water is contaminated in any way discontinue use of the appliance and contact an authorized technician or licensed professional Water pH between 6 5 and 8 5 pH levels below 6 5 can cause an increase in the rate of corrosion pH of 8 5 or higher can potentially cause lime scale build up Failure of electric elements due to lime ...

Страница 6: ...ages Amperages Refers to Model Type and Gallon Size See Table 2 for Model Specifications and Dimensions Specifications and Dimensions Water Temperature Ratings Residential Models Storage Capacity A B C D E Safety Listing Hot Cold Inlets Shipping Weight Lbs Est Min Delivered Temp Max Delivered Temp High Temp Limit ARIER040C2X045N 40 5 3 4 46 54 1 4 19 1 2 8 UL 174 3 4 NPT 104 110oF 43 3 C 150oF 65 ...

Страница 7: ...igure 3 for the electric water heater to operate properly Failure to install these fittings properly will result in improper water heater operation possible substantial property damage and increased costs Service calls to repair the installation and properly install these fittings ARE NOT COVERED by water heater warranty Improper installation WILL VOID the water heater warranty ...

Страница 8: ... the water heater Replacing the relief valve will not correct thermal expansion A potable hot water expansion tank is required to offset thermal expansion Expansion tanks are designed with an air cushion built in that compresses as system pressure increases thereby relieving the overpressure condition and eliminating repeated operation of the relief valve This expansion tank should be installed in...

Страница 9: ... RE INSPECT THE T P VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE AND OR PRESSURE BUILD UP WHICH CAN RESULT IN PROPERTY DAMAGE SERIOUS PERSONAL INJURY OR DEATH Do not thread a cap or plug into the relief valve or block relief valve outlet line under any circumstances Explosion and property damage serious injury or death may result F Scalding An ASSE 1017 or ASSE 1070 temperature limiting or...

Страница 10: ... the heater is specified on the rating label of the water heater Consult your local power company to determine if your electrical service is adequate for the additional load of the heater Tank must be full of water before the power is turned on Heating elements will be damaged if energized for even a short time while tank is dry Failures due to dry firing ARE NOT covered by warranty Be sure to gro...

Страница 11: ...back in service Failure to do so could result in property damage severe personal injury or death B Thermostat Adjustment and ECO Reset There are two thermostats on dual element heaters If temperature adjustment is necessary TURN OFF POWER TO HEATER remove black access cover and insulation The thermostat protective cover Failure to disconnect the power from the water heater before attempting to adj...

Страница 12: ...er back on to the water heater Failure to refill the tank before restoring power to the water heater will result in damage to the heating elements and property damage Such damages ARE NOT covered by warranty Part 7 Maintenance Considerations To avoid electric shock disconnect electrical supply before performing maintenance To avoid severe burns allow heater to cool before performing maintenance NO...

Страница 13: ...here have been any issues with the water heater Diagnose any heater issues and repair replace parts as necessary 2 Check the water heater and related plumbing for leaks Repair any that are found 3 Check the area around the water heater for flammable liquids or combustible materials If any are found remove from the area 4 Check the heating elements while the heater is in operation If the elements a...

Страница 14: ...ermostat setting or replace 3 Tighten wire connections Improper wiring Check and rewire per Wiring Detail Not Enough Hot Water Heater undersized Reduce rate of heater use Defective element s Check amperage replace element if low Miswired or defective thermostat causing only one element to work Check wiring or replace thermostat Water Too Hot or Not Hot Enough Thermostat setting too high or low Cha...

Страница 15: ...HERMOSTAT PROTECTIVE COVER LOWER U MODELS ONLY 6060P 636 6 ACCESS PANEL 6060P 187 7 SCREWS ACCESS PANEL 6075P 006 8 MOUNTING BRACKET 6060P 955 MOUNTING BRACKET U models only 6060P 956 9 ELECTRIC ELEMENT 3000W 6060P 939 ELECTRIC ELEMENT 4500W 6060P 938 ELECTRIC ELEMENT 5500W 6060P 937 10 DRAIN VALVE 6070P 009 11 DIP TUBE 40 GAL DIP TUBE 52 GAL 6060P 1034 6060P 1035 12 NIPPLE HEAT TRAP 6060P 1038 13...

Страница 16: ...warranty extends only to water heaters utilized in heating applications that have been properly installed by qualified professionals based upon the manufacturer s installation instructions G It is expressly agreed between Ariston and the Owner that repair replacement or refund are the exclusive remedies of the Owner OWNER RESPONSIBILITIES The Owner or Qualified Installer Service Technician must 1 ...

Страница 17: ... original receipt complete model and serial numbers and the date of installation of the water heater in addition to an explanation of the water heater problem Warranty coverage is subject to validation of in warranty coverage by Ariston claims department personnel All alleged defective or malfunctioning components must be returned to Ariston via the local distribution channels where the original p...

Страница 18: ...lation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer Installation Notes IMPORTANT Customer Please only sign after the qualified installer service technician has fully reviewed the installation safety proper operation and maintenance of the system If the system has any problems please call the qualifie...

Отзывы: