Pre-Installation

 - continued

 

Typical equipment required:    

electric drill, screwdriver, tape measure, spirit level

duct tape, jig saw, ladder 

(if ducting)

Torch 

(If natural lighting is insufficient)

Contents of packaging: 

1x Range hood 
1x

 

φ

150mm round ducting

7x Wall Plugs 

7x Long Wall Screws 
3x Chimney Screws – Pointed End, 12mm in length 

2x Chimney Bracket Screw – Flat End 

2x Chimney (top & bottom) 
2x Mounting Brackets, (1x Wall Mount, 1x Chimney Mount) 

Appliance Details: 

Voltage & Frequency: 220-240V 50Hz 
Lamp max: 2x2W DC12V 
Rated Input Power: 274W 

Ducting Options 

The method of ducting should be carefully considered before installing the range hood.  The guide below 
recommends the ducting components to use for all common ducting configurations - through the top of the home 

(for the roof and soffit) and through the rear of the home.  150mm round ducting should be used in conjunction 

with this model range hood.  Alternatively this range hood can be operated in recirculation mode (see 

Recirculation mode). 

The highlighted area in the table below gives the recommended Uniduct item numbers for different 

mounting and outlet options. 

Duct mounting option

 

Rear 

Top (roof) 

Top (soffit/eave) 

Extra lengths and/or bends may be required, depending on the length required and whether there is any 

structural material in the run e.g. rafters. Please note that this chart is designed as a guide. 

Содержание ACRH91BIX

Страница 1: ...1 Description WALL CANOPY Model Numbers ACRH91BIX RWC Issue F Model may vary slightly from images pictured All measurements are in mm...

Страница 2: ...liance from the outlet 12 It is recommended to operate the range hood prior to cooking 13 It is recommended to leave the range hood in operation for 15 minutes after cooking is terminated in order to...

Страница 3: ...carefully considered before installing the range hood The guide below recommends the ducting components to use for all common ducting configurations through the top of the home for the roof and soffi...

Страница 4: ...orting surface of the cooking surface for the cooking vessels of the hob and the lowest part of the range hood must be 650mm If the installation instructions for gas hobs specify a greater distance th...

Страница 5: ...an adequate length of 150mm round duct into the recessed area of the air outlet adapter 2 Secure the duct to the air outlet using duct tape 3 Install the charcoal filters after fitting chimney Please...

Страница 6: ...test There are 10 speed settings Cleaning and Maintenance General Maintenance Switch off the canopy before cleaning or maintenance To prevent surface damage never use abrasive or oil based liquid clea...

Страница 7: ...efit cord to power outlet Switch power on Lights not working Broken Faulty globes Replace globes Contact Ariston Service Insufficient suction The distance between the range hood and the gas top is to...

Отзывы: