Don’t make cable joints in inaccessable places like ceilings ect.
Provide adequate documentation of the cable layout,DP layout & MDF Layout.
Never work alone at a customers premises after hours (Ask for security presece.
Never risk your safety your life is precious.
Be insured against Liability ( Workman's compensation & Goods in Transist.)
The installation site should not be in areas subject to static electricity (eg. Dry
copiers), or vibration (eg. Heavy machinery).
Do not use the PABX as a Shelf!
Do not use 2
nd
hand Line termination Equipment ( Krone)
Calculate 30% Spare Capacity into the reticulation for future expansion.
Two dedicated (220VAC/50Hz) outlet with 10 Amp circuit breakers are required.
(
One for System Power and one for ancillary equipment eg: External Music for soldering iron
for technical use ect
)A separate earth is also required in addition to the third earth wire
on the AC circuit. If a music source or optional external paging equipment is installed
it must be connected to an
separate
AC circuit.
THE SYSTEM
POWER SUPPLY SHOULD BE CONNECTED TO A DEDICATED
AC
OUTLET.