7. Shrink the tubing with a heat gun.
Figure 22: Lug Preparation
1
Insulated wire
3
Lug
B
1/2”
2
Heat-shrink tubing
A
1/4”
C
5/8”
Note: Dimension B is the width of the lug (not visible on the right angle lug).
4.3.2.2
Connecting a DC Power Supply to Power Source
Figure 23: DC PSU Connection Example
displays an example of connecting a PSU. To connect a DC
power supply to a power source, perform the following:
1. Prepare the stranded wiring (
).
2. Attach the appropriate lugs to the source DC wires.
3. Connect the DC-input wires to the appropriate terminals using the specified torque (
) in the following order.
Note: Remove terminal covers as needed.
a. Ground wire to the Protective Earth (PE ) terminal.
b. Negative source DC cable to the negative (- / -48V) terminal.
c. Positive (+) source DC cable to the positive (+ / Rtn) terminal.
4. Replace the terminal covers as required.
Figure 23: DC PSU Connection Example
4.4
Connecting Serial and Management Cables
The accessory kit includes the following cables:
•
RJ-45 to DB-9 serial adapter cable.
•
RJ-45 Ethernet cable.
Table 7: RJ-45 to DB-9 Connections
lists the pin connections of the RJ-45 to DB-9 adapter cable.