background image

 

a person responsible for their safety. Children should 
be supervised to ensure that they do not play with the 
appliance. 

12. Please keep the product from the wall or other 

barriers in a minimum distance of 50 cm. 

13. Please install the appliance following the country 

wiring laws. 

 
OPERATING INSTRUCTION 

 

1. Control panel

 

2. Air outlet 

3. Handel 

4. Front housing 

 

 

 

 

 

 

 

5. Air Inlet / Back housing 

6. Drain hole 

7. Water tank 

 

   
 

 

3

CONTROL PANEL DESCRIPTION 

 
OPERATING INSTRUCTION 

1. Power 

Press the key to turn “on” or “off”. 

2. Fan 

Speed 

Press the key to choose high speed (HI) or low speed (LOW).

 

3.  Timer  

a. Press the key to set time you need (1 to 24 hours), and then the related 

idicating light will illuminate.

 

b. When setting timer in stand-by mode, the unit will be turned on 

automatically; when setting timer in operating mode, the unit will be turned 

off automatically. 

c. If pressing the power key to turn on/off the unit before time finishes 

counting down, the setting timer will be canceled. 

4.  Humidity Setting 

Press the key to set the relative humidity you need. (From RH50%, 60%, 

70%, 80%, comfort mode [AU], to continuous dehumidification [CO]. 

When ambient humidity is lower than setting humidity by 3%, 

compressor will stop automatically, and return working until the ambient 

humidity is higher than setting humidity by 3%. 

Comfort Mode [AU] 

a. When ambient temperature is lower than 5

, compressor will stop 

working.

 

Содержание PD70-LAE

Страница 1: ...users 5 Disconnect the appliance from power supply before moving or cleaning the product and also when the product is not in used 6 Please operate the product with specified electricity voltage 7 Please use this product only for household appliance and follow the designed purpose 8 Do not put any stuff on the product 9 In order to avoid water leakage please clean the water tank before moving the p...

Страница 2: ...the key to set time you need 1 to 24 hours and then the related idicating light will illuminate b When setting timer in stand by mode the unit will be turned on automatically when setting timer in operating mode the unit will be turned off automatically c If pressing the power key to turn on off the unit before time finishes counting down the setting timer will be canceled 4 Humidity Setting Press...

Страница 3: ... unit because it takes 10 minutes to reposition If the unit still does not start after 10 minutes please ask your local distributor service station to repair 6 When the dehumidifier is operating it s a normal situation that the working compressor may cause some heat and bring the ambient temperature up 7 When the product is defrosting related indicating light will illuminate And during the defrost...

Страница 4: ... filter with cool water cooler than 40 but not gasoline or alcohol every two weeks and put filter back after it air dried naturally 7 SPECIFICATIONS MODEL SPECIFICATION PD70 LAE POWER SUPPLY 220 240V 50Hz POWER INPUT EN60335 1350W RUNNING CURRENT 5 3A NET WEIGHT 24Kg MOISTURE REMOVAL 30 RH80 70 liters day CABINETDIMEMSION 481W x 286D x 628H TEMP RANGE FOR USE 5 32 WATER TANK CAPACITY 7 2L CE N 842...

Отзывы: