Some Hints for a trouble free operation;
Do not block the flame nozzle complete when you are filling the wood logs.
If you have a bridge problem and the wood logs are stay at top than try to use half length wood
logs, eg: for 50 cm combustion chamber use 25 cm logs.
At first ignition keep the upper door open up to you have strong reverse flame
Heating up and start operation
1.
Press the power switch button
of the panel to “on (1)” position.
2.
Fill the wood filling volume up to bottom of the door line. Try to keep flame nozzle open.
3.
Fire the woods.
4.
Press the start button
on the panel.
5.
Leave the upper wood filling door 4 to 10 cm opened up to you have a strong flame.
6.
Fill the woods full or as much as you need.
7.
Close the boiler door.
8.
Press the function button
until to
figure seen right corner on the screen
9.
Set desired boiler water temperature with the
buttons.
10. Do not set the boiler temperature below the 7
5 °C because of the condensation problem.