GB - 23
Replace Fuse (926104, 105)
1. Remove the two screws and the cover
plate from beneath the battery.
2. Locate the fuse holder on the wiring
harness and remove the fuse.
3. Install a new fuse of the same amp-
rating and type.
4. Replace the cover plate and secure in
position with the two screws removed in
step 1.
NOTE:
Make sure the wire harness does not
get pinched between the cover plate and the
auger housing.
SCRAPER BLADE
IMPORTANT:
Damage to auger/impeller
housing will result if blade wears down too
far.
Scraper blade is adjustable to compensate
for wear.
To adjust scraper blade:
1. Tip unit back onto handlebar, support
housing and loosen nuts retaining blade.
2. Adjust skid shoes to fully raised position
(housing closest to ground).
3. Reposition scraper blade flush with skid
shoes and tighten lock nuts.
SKID SHOES
(Figure 21)
Skid Shoes should be adjusted as conditions
require.
1. Position unit on a hard, flat, smooth level
surface.
2. Adjust skid shoes by inserting a spacer
of desired thickness under center of
scraper blade, loosen skid shoe
hardware, slide skid shoes to flat
surface. Allow 1/8 in. (3 mm) between
scraper blade and hard smooth
surfaces. Allow 1 in. (25 mm) between
scraper blade and uneven or gravel
surfaces. Retighten hardware.
NOTE:
Keep housing level by adjusting skid
shoes equally.
Figure 19
OS7450
Cover plate and
mounting screws.
Figure 20
Fuse and fuse holder.
OS7455
SERVICE AND ADJUSTMENTS
WARNING:
AVOID INJURY. Read
and understand the entire
Safety
section before proceeding.
Figure 21
2
1
OS0483
1. Skid Shoes
2. Skid Shoe Hardware